MEAN WELL RCP-1600-24 1608W 24V 67A Rack Power

Part numberRCP-1600-24
Output voltage 24 V
Rated current 67 A
Rated power 1608 W
$1,113.63Excluding tax and shipping
Ships in 3–5 business daysLead time is the time from order to dispatch, and does not include transit time.
Request bulk quote

Procurement confidence

  • Genuine product Sourced through our documented supply chain.
  • Worldwide shipping Export documentation handled for you.
  • Commercial invoice Available for every order.
  • Specification support Talk to someone who reads datasheets.
Output
Output voltage 24 V
Rated current 67 A
Rated power 1608 W
AC input range 90–264 VAC
Typical efficiency 91 %
Mechanical
Operating temperature -30 to 70 °C
Power factor correction Supported
Dimensions (L × W × H) 300 × 85 × 41 mm

Is this model right for you?

Within the RCP-1600 series, the RCP-1600-24 differs from the RCP-1600-12 and RCP-1600-48 by output voltage, output current, output adjustment range, rated power, typical efficiency, and ripple and noise. RCP-1600-24: 24 V, 67 A, 23.5 to 30 V, 1608 W, 91%, 200 mVp-p. RCP-1600-12: 12 V, 125 A, 11.5 to 15 V, 1500 W, 88.5%, 150 mVp-p. RCP-1600-48: 48 V, 33.5 A, 47.5 to 58.8 V, 93%, 300 mVp-p.

Product overview

The RCP-1600-24 is part of the RCP-1600 series from MEAN WELL. It provides a 24 V output with a 67 A output current and 1608 W rated power. The output adjustment range is 23.5 to 30 V. The input voltage range is 90 to 264 VAC and 250 to 370 VDC, with a frequency range of 47 to 63 Hz. Typical efficiency is 91% and ripple and noise is 200 mVp-p. Dimensions are 300 × 85 × 41 mm and net weight is 1870 g.

Where this model fits

The RCP-1600-24 is used in Telecom & Datacom applications. It provides a 24 V output at 67 A with 1608 W rated power. The input voltage range is 90 to 264 VAC and 250 to 370 VDC. Dimensions are 300 × 85 × 41 mm and net weight is 1870 g.

Complete technical specifications

Rev. 2026-03-04
Output
Output voltage 24 V
Rated current 67 A
Rated power 1608 W
Voltage adjustment range 23.5–30 V
Ripple & noise 200 mVp-p
Input
AC input range 90–264 VAC
DC input range 250–370 VDC
Frequency range 47–63 Hz
Typical efficiency 91 %
Power factor 0.97
Power factor correction Supported
Environmental
Operating temperature -30 to 70 °C
Storage temperature -40 to 85 °C
Operating humidity 20–90 % RH
Vibration 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
Mechanical
Dimensions (L × W × H) 300 × 85 × 41 mm
Net weight 1870.0 g
Safety & compliance
Safety standards UL62368-1, CAN/CSA C22.2 No. 62368-1, TUV BS EN/EN62368-1, EAC TP TC 004 approved

These approvals are recorded for the series as a whole. Where a line names particular models or ratings, it applies only to those — read it against this part number, and ask us for the certificate if your approval process needs it.

Identification
Part number RCP-1600-24
Brand MEAN WELL
Category AC/DC Rack Power
Series RCP-1600

Approvals and compliance

From the manufacturer's datasheet for this series

United States

  • UL

    UL Listing or Recognition means UL Solutions tested samples against the applicable UL safety standard and audits the factory that builds them. A UL file number is the usual evidence an inspector or specifier asks for in North America.

Canada

  • CSA

    Certification to a CSA C22.2 standard, the Canadian counterpart of the UL series. Datasheets cite the specific C22.2 number, which is how you tell a power-supply certificate from a luminaire-controlgear one.

Europe

  • TÜV

    A TÜV certificate is third-party testing against the European EN standard. It is the evidence behind a CE declaration rather than a replacement for it: CE remains the manufacturer's own declaration, and the TÜV report is what makes that declaration defensible.

Eurasian Economic Union

  • EAC

    Conformity with the Eurasian Economic Union technical regulations, covering Russia, Belarus, Kazakhstan, Armenia and Kyrgyzstan. TP TC 004 is the low-voltage regulation and TP TC 020 the electromagnetic-compatibility one, so which number appears tells you what was assessed.

Isolation and electromagnetic compatibility
Withstand voltage I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC (0.5KVAC for 12V)
EMC emission Parameter Standard Test Level / Note

Standards certified against

  • EN62368-1
  • UL62368-1
Read the datasheet's exact wording

UL62368-1, CAN/CSA C22.2 No. 62368-1, TUV BS EN/EN62368-1, EAC TP TC 004 approved

Reproduced unedited from the manufacturer's datasheet. Where an approval covers only some models, the wording says so. Ask us for the certificate itself if your approval process needs it.

Certificates

Certificate copy supplied with this model.
  • CE · R50453592

    100%
    CE certificate R50453592

    CE · Certificate number R50453592

Ordering & shipping information

Order and delivery terms
Part number RCP-1600-24
Minimum order quantity 1
Country of origin China
Typical packed weight 2242 g
Unit weight 1870 g

RCP-1600 model comparison

View all models
ModelOutput voltageRated currentRated powerPriceAvailability
RCP-1600-1212 V125 A1500 W$1,113.63
Ships in 3–5 business days
RCP-1600-24 Currently viewing24 V67 A1608 W$1,113.63
Ships in 3–5 business days

RCP-1600-24 provides 24 V output and 67 A output current; RCP-1600-12 provides 12 V and 125 A; RCP-1600-48 provides 48 V and 33.5 A.

RCP-1600-24 has a 23.5 to 30 V output adjustment range; RCP-1600-12 has 11.5 to 15 V; RCP-1600-48 has 47.5 to 58.8 V.

RCP-1600-24 has 1608 W rated power; RCP-1600-12 has 1500 W.

RCP-1600-24 has 91% typical efficiency and 200 mVp-p ripple and noise; RCP-1600-12 has 88.5% and 150 mVp-p; RCP-1600-48 has 93% and 300 mVp-p.

Request a bulk quote

Tell us the quantity and target date and we will come back with pricing, lead time and stock position for this part number.

  1. 1 We confirm the part number and quantity against current stock.
  2. 2 You receive pricing, lead time and freight options by email.
  3. 3 Approve the quotation and we issue the invoice and shipping documents.

Request a quote for RCP-1600-24

Confirm quantity and destination and we will come back with pricing and lead time.

Quoting RCP-1600-24 View
Have a BOM? Reply to our confirmation email with the file attached.
We use your details only to answer this request.

Technical data source

Primary source
MEAN WELL
Datasheet revision
2026-03-04
Last verified

View the manufacturer datasheet How we source and verify product data

Specifications are transcribed from the manufacturer datasheet and are subject to change without notice. The current manufacturer datasheet governs in case of any discrepancy.