Output
Output voltage 12 V
Rated current 125 A
Rated power 1500 W
AC input range 90–264 VAC
Typical efficiency 88.5 %
Mechanical
Operating temperature -30 to 70 °C
Power factor correction Supported
Dimensions (L × W × H) 300 × 85 × 41 mm

Is this model right for you?

Within the RCP-1600 series, the RCP-1600-12 lists 12 V output and 125 A output current. The RCP-1600-24 lists 24 V output and 67 A output current, while the RCP-1600-48 lists 48 V output and 33.5 A output current. Rated power is 1500 W for the RCP-1600-12 and 1608 W for the RCP-1600-24 and RCP-1600-48.

Product overview

The RCP-1600-12 provides a 12 V output with 125 A output current and 1500 W rated power. The output adjustment range is 11.5 ~ 15V, and ripple and noise is 150 mVp-p. The input voltage range is 90 ~ 264VAC 250 ~ 370VDC at 47 ~ 63Hz. Typical efficiency is 88.5%. Dimensions are 300 × 85 × 41 mm and net weight is 1870 g.

Where this model fits

The RCP-1600-12 is used in Telecom & Datacom applications. Its operating temperature range is -30 to 70 °C, and its humidity range is 20 to 90%. The product measures 300 × 85 × 41 mm and weighs 1870 g.

Complete technical specifications

Rev. 2026-03-04
Output
Output voltage 12 V
Rated current 125 A
Rated power 1500 W
Voltage adjustment range 11.5–15 V
Ripple & noise 150 mVp-p
Input
AC input range 90–264 VAC
DC input range 250–370 VDC
Frequency range 47–63 Hz
Typical efficiency 88.5 %
Power factor 0.97
Power factor correction Supported
Environmental
Operating temperature -30 to 70 °C
Storage temperature -40 to 85 °C
Operating humidity 20–90 % RH
Vibration 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
Mechanical
Dimensions (L × W × H) 300 × 85 × 41 mm
Net weight 1870.0 g
Safety & compliance
Safety standards UL62368-1, CAN/CSA C22.2 No. 62368-1, TUV BS EN/EN62368-1, EAC TP TC 004 approved

These approvals are recorded for the series as a whole. Where a line names particular models or ratings, it applies only to those — read it against this part number, and ask us for the certificate if your approval process needs it.

Identification
Part number RCP-1600-12
Brand MEAN WELL
Category AC/DC Rack Power
Series RCP-1600

Approvals and compliance

From the manufacturer's datasheet for this series

United States

  • UL

    UL Listing or Recognition means UL Solutions tested samples against the applicable UL safety standard and audits the factory that builds them. A UL file number is the usual evidence an inspector or specifier asks for in North America.

Canada

  • CSA

    Certification to a CSA C22.2 standard, the Canadian counterpart of the UL series. Datasheets cite the specific C22.2 number, which is how you tell a power-supply certificate from a luminaire-controlgear one.

Europe

  • TÜV

    A TÜV certificate is third-party testing against the European EN standard. It is the evidence behind a CE declaration rather than a replacement for it: CE remains the manufacturer's own declaration, and the TÜV report is what makes that declaration defensible.

Eurasian Economic Union

  • EAC

    Conformity with the Eurasian Economic Union technical regulations, covering Russia, Belarus, Kazakhstan, Armenia and Kyrgyzstan. TP TC 004 is the low-voltage regulation and TP TC 020 the electromagnetic-compatibility one, so which number appears tells you what was assessed.

Isolation and electromagnetic compatibility
Withstand voltage I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC (0.5KVAC for 12V)
EMC emission Parameter Standard Test Level / Note

Standards certified against

  • EN62368-1
  • UL62368-1
Read the datasheet's exact wording

UL62368-1, CAN/CSA C22.2 No. 62368-1, TUV BS EN/EN62368-1, EAC TP TC 004 approved

Reproduced unedited from the manufacturer's datasheet. Where an approval covers only some models, the wording says so. Ask us for the certificate itself if your approval process needs it.

Certificates

Certificate copy supplied with this model.
  • CE · R50453592

    100%
    CE certificate R50453592

    CE · Certificate number R50453592

Ordering & shipping information

Order and delivery terms
Part number RCP-1600-12
Minimum order quantity 1
Country of origin China
Typical packed weight 2242 g
Unit weight 1870 g

RCP-1600 model comparison

View all models
ModelOutput voltageRated currentRated powerPriceAvailability
RCP-1600-12 Currently viewing12 V125 A1500 W$1,113.63
Ships in 3–5 business days
RCP-1600-2424 V67 A1608 W$1,113.63
Ships in 3–5 business days

RCP-1600-12: 12 V output, 125 A output current; RCP-1600-24: 24 V output, 67 A output current.

RCP-1600-12: 12 V output, 125 A output current; RCP-1600-48: 48 V output, 33.5 A output current.

RCP-1600-12: 1500 W rated power; RCP-1600-24: 1608 W rated power.

RCP-1600-12: 1500 W rated power; RCP-1600-48: 1608 W rated power.

Request a bulk quote

Tell us the quantity and target date and we will come back with pricing, lead time and stock position for this part number.

  1. 1 We confirm the part number and quantity against current stock.
  2. 2 You receive pricing, lead time and freight options by email.
  3. 3 Approve the quotation and we issue the invoice and shipping documents.

Request a quote for RCP-1600-12

Confirm quantity and destination and we will come back with pricing and lead time.

Quoting RCP-1600-12 View
Have a BOM? Reply to our confirmation email with the file attached.
We use your details only to answer this request.

Technical data source

Primary source
MEAN WELL
Datasheet revision
2026-03-04
Last verified

View the manufacturer datasheet How we source and verify product data