MEAN WELL LRS-600N2-12 600W 12V 50A Enclosed Type

Part numberLRS-600N2-12
Output voltage 12 V
Rated current 50 A
Rated power 600 W
$86.22Excluding tax and shipping
Ships in 3–5 business daysLead time is the time from order to dispatch, and does not include transit time.
Request bulk quote

Procurement confidence

  • Genuine product Sourced through our documented supply chain.
  • Worldwide shipping Export documentation handled for you.
  • Commercial invoice Available for every order.
  • Specification support Talk to someone who reads datasheets.
Output
Output voltage 12 V
Rated current 50 A
Rated power 600 W
Typical efficiency 90 %
Mechanical
Operating temperature -20 to 65 °C
Dimensions (L × W × H) 225 × 124 × 41 mm

Is this model right for you?

Within the LRS-600N2 series, the LRS-600N2-12 differs from siblings by output voltage and current. LRS-600N2-12: 12 V, 50 A; LRS-600N2-24: 24 V, 25 A; LRS-600N2-36: 36 V, 16.6 A; LRS-600N2-48: 48 V, 12.5 A. Ripple and noise also differ: 200mVp-p for the 12 V model, 240mVp-p for 24 V, and 360mVp-p for 36 V and 48 V.

Product overview

The LRS-600N2-12 provides a 12 V output with 50 A output current and 600 W rated power. Its output adjustment range is 11.4 ~ 13.2V, and typical efficiency is 90%. Ripple and noise are 200mVp-p. The product measures 225 × 124 × 41 mm and has a net weight of 950 g.

Where this model fits

The LRS-600N2-12 is used in Industrial Automation and Security & Surveillance applications. Its 12 V output and 50 A output current are the electrical figures supplied for this model, alongside a 600 W rated power and 200mVp-p ripple and noise.

Complete technical specifications

Rev. 2025-09-12
Output
Output voltage 12 V
Rated current 50 A
Rated power 600 W
Voltage adjustment range 11.4–13.2 V
Ripple & noise 200 mVp-p
Input
AC input range 90 ~ 132VAC / 180 ~ 264VAC by switch 255 ~ 370VDC (swith on 230VAC)
DC input range 255–370 VDC
Frequency range 47–63 Hz
Typical efficiency 90 %
Environmental
Operating temperature -20 to 65 °C
Storage temperature -40 to 85 °C
Operating humidity 20–90 % RH
Vibration 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
Mechanical
Dimensions (L × W × H) 225 × 124 × 41 mm
Net weight 950.0 g
Safety & compliance
Safety standards BS IEC/UL 62368-1, EAC TP TC 004, BIS IS13252(Part1):2010/IEC60950-1:2005(except for 48V), BSMI CNS15598-1,GB 4943.1, BS EN/EN61558-1,BS EN/EN61558-2-16, design refer to AS/NZS61558.1/2.16,AS/NZS62368.1

These approvals are recorded for the series as a whole. Where a line names particular models or ratings, it applies only to those — read it against this part number, and ask us for the certificate if your approval process needs it.

Identification
Part number LRS-600N2-12
Brand MEAN WELL
Category AC/DC Enclosed Type
Series LRS-600N2

Approvals and compliance

From the manufacturer's datasheet for this series

United States

  • UL

    UL Listing or Recognition means UL Solutions tested samples against the applicable UL safety standard and audits the factory that builds them. A UL file number is the usual evidence an inspector or specifier asks for in North America.

Taiwan

  • BSMI

    Taiwan's mandatory inspection mark, issued against a CNS standard. CNS 15598-1 is the CNS transposition of IEC 62368-1, which is why the two numbers usually appear together.

Eurasian Economic Union

  • EAC

    Conformity with the Eurasian Economic Union technical regulations, covering Russia, Belarus, Kazakhstan, Armenia and Kyrgyzstan. TP TC 004 is the low-voltage regulation and TP TC 020 the electromagnetic-compatibility one, so which number appears tells you what was assessed.

India

  • BIS

    Registration under India's Compulsory Registration Scheme, against an IS standard. IS 13252 is the Indian transposition of IEC 60950-1 and IS 15885 of IEC 61347, so the IS number identifies the product category.

    Covers only part of this series: except for 48V

An approval above is held by only some models in this series. The datasheet's own wording is quoted beside the mark; read it against this part number, and ask us for the certificate if your approval process needs it.

Isolation and electromagnetic compatibility
Withstand voltage I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
Isolation resistance I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC / 25℃/ 70% RH
EMC emission Compliance to EAC TP TC 020, BSMI CNS15936
EMC immunity Compliance to EAC TP TC 020

Standards certified against

  • CNS15598-1
  • EN61558-1
  • EN61558-2-16
  • GB 4943.1
  • IEC60950-1
  • IS13252
  • UL 62368-1

Designed to reference

The datasheet lists these as design references. The series was built to them but has not been certified to them, so do not treat them as approvals.

AS/NZS61558.1/2.16,AS/NZS62368.1

Read the datasheet's exact wording

BS IEC/UL 62368-1, EAC TP TC 004, BIS IS13252(Part1):2010/IEC60950-1:2005(except for 48V), BSMI CNS15598-1,GB 4943.1, BS EN/EN61558-1,BS EN/EN61558-2-16, design refer to AS/NZS61558.1/2.16,AS/NZS62368.1

Reproduced unedited from the manufacturer's datasheet. Where an approval covers only some models, the wording says so. Ask us for the certificate itself if your approval process needs it.

Certificates

Certificate copy supplied with this model.
  • CE · R50453592

    100%
    CE certificate R50453592

    CE · Certificate number R50453592

Ordering & shipping information

Order and delivery terms
Part number LRS-600N2-12
Minimum order quantity 1
Country of origin China
Typical packed weight 1183 g
Unit weight 950 g

LRS-600N2 model comparison

View all models
ModelOutput voltageRated currentRated powerPriceAvailability
LRS-600N2-12 Currently viewing12 V50 A600 W$86.22
Ships in 3–5 business days
LRS-600N2-3636 V16.6 A597.6 W$92.85
Ships in 3–5 business days
LRS-600N2-2424 V25 A600 W$86.22
Ships in 3–5 business days

LRS-600N2-12 lists 12 V output and 50 A output current; LRS-600N2-24 lists 24 V output and 25 A output current.

LRS-600N2-12 lists 12 V output and 50 A output current; LRS-600N2-36 lists 36 V output and 16.6 A output current.

LRS-600N2-12 lists 12 V output and 50 A output current; LRS-600N2-48 lists 48 V output and 12.5 A output current.

LRS-600N2-12 lists 200mVp-p ripple and noise; LRS-600N2-24 lists 240mVp-p, and LRS-600N2-36 and LRS-600N2-48 list 360mVp-p.

Request a bulk quote

Tell us the quantity and target date and we will come back with pricing, lead time and stock position for this part number.

  1. 1 We confirm the part number and quantity against current stock.
  2. 2 You receive pricing, lead time and freight options by email.
  3. 3 Approve the quotation and we issue the invoice and shipping documents.

Request a quote for LRS-600N2-12

Confirm quantity and destination and we will come back with pricing and lead time.

Quoting LRS-600N2-12 View
Have a BOM? Reply to our confirmation email with the file attached.
We use your details only to answer this request.

Technical data source

Primary source
MEAN WELL
Datasheet revision
2025-09-12
Last verified

View the manufacturer datasheet How we source and verify product data

Specifications are transcribed from the manufacturer datasheet and are subject to change without notice. The current manufacturer datasheet governs in case of any discrepancy.