MEAN WELL LRS-100N2-24 100.8W 24V 4.2A Enclosed Type

Part numberLRS-100N2-24
Output voltage 24 V
Rated current 4.2 A
Rated power 100.8 W
$23.37Excluding tax and shipping
Ships in 3–5 business daysLead time is the time from order to dispatch, and does not include transit time.
Request bulk quote

Procurement confidence

  • Genuine product Sourced through our documented supply chain.
  • Worldwide shipping Export documentation handled for you.
  • Commercial invoice Available for every order.
  • Specification support Talk to someone who reads datasheets.
Output
Output voltage 24 V
Rated current 4.2 A
Rated power 100.8 W
AC input range 85–264 VAC
Typical efficiency 90 %
Mechanical
Operating temperature -30 to 70 °C
Dimensions (L × W × H) 129 × 97 × 30 mm

Is this model right for you?

Within the LRS-100N2 series, the LRS-100N2-24 provides a 24 V output at 4.2 A. The LRS-100N2-12 provides 12 V at 8.5 A, the LRS-100N2-36 provides 36 V at 2.8 A, and the LRS-100N2-48 provides 48 V at 2.1 A. Output adjustment ranges also differ: 21.6 to 28.8 V for the 24 V model, 10.2 to 13.8 V for the 12 V model, 32.4 to 39.6 V for the 36 V model, and 43.2 to 52.8 V for the 48 V model.

Product overview

The LRS-100N2-24 is an AC/DC Enclosed Type product in the LRS-100N2 series. It provides a 24 V output with a 4.2 A output current and 100.8 W rated power. The output adjustment range is 21.6 to 28.8 V, and typical efficiency is 90%. Ripple and noise are 150 mVp-p. The input frequency range is 47 to 63 Hz. Dimensions are 129 × 97 × 30 mm and net weight is 350 g.

Where this model fits

The LRS-100N2-24 is used in Industrial Automation and Security & Surveillance applications. It provides a 24 V output at 4.2 A with 100.8 W rated power. The operating temperature range is -30 to 70 °C, and the humidity range is 20 to 90%. Dimensions are 129 × 97 × 30 mm and net weight is 350 g.

Complete technical specifications

Rev. 2025-04-07
Output
Output voltage 24 V
Rated current 4.2 A
Rated power 100.8 W
Voltage adjustment range 21.6–28.8 V
Ripple & noise 150 mVp-p
Input
AC input range 85–264 VAC
DC input range 120–373 VDC
Frequency range 47–63 Hz
Typical efficiency 90 %
Environmental
Operating temperature -30 to 70 °C
Storage temperature -40 to 85 °C
Operating humidity 20–90 % RH
Vibration 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
Mechanical
Dimensions (L × W × H) 129 × 97 × 30 mm
Net weight 350.0 g
Safety & compliance
Safety standards CB: IEC62368-1, IEC61558-1, IEC61558-2-16, IEC60335-1 TUV: BS EN/EN62368-1, BS EN/EN61558-1/-2-16, BS EN/EN60335-1 UL: UL62368-1 CQC: GB4943.1 BSMI: CNS15598-1 EAC: TP TC 004, S/NZS62368.1(by CB) BIS: IS 13252(Part1):2010/IEC 60950-1:2005(except for 48V) RCM: Designed refer to AS/NZS 61558.1/2.16, AS/NZS62368.1

These approvals are recorded for the series as a whole. Where a line names particular models or ratings, it applies only to those — read it against this part number, and ask us for the certificate if your approval process needs it.

Identification
Part number LRS-100N2-24
Brand MEAN WELL
Category AC/DC Enclosed Type
Series LRS-100N2

Approvals and compliance

From the manufacturer's datasheet for this series

United States

  • UL

    UL Listing or Recognition means UL Solutions tested samples against the applicable UL safety standard and audits the factory that builds them. A UL file number is the usual evidence an inspector or specifier asks for in North America.

Europe

  • TÜV

    A TÜV certificate is third-party testing against the European EN standard. It is the evidence behind a CE declaration rather than a replacement for it: CE remains the manufacturer's own declaration, and the TÜV report is what makes that declaration defensible.

International

  • CB Scheme

    A CB Test Certificate reports testing against the IEC standard and is accepted by member certification bodies as the basis for a national approval. It shortens a new-country approval rather than granting market access by itself, so it is the most useful item on this list when you are entering a market that is not shown here.

Taiwan

  • BSMI

    Taiwan's mandatory inspection mark, issued against a CNS standard. CNS 15598-1 is the CNS transposition of IEC 62368-1, which is why the two numbers usually appear together.

Eurasian Economic Union

  • EAC

    Conformity with the Eurasian Economic Union technical regulations, covering Russia, Belarus, Kazakhstan, Armenia and Kyrgyzstan. TP TC 004 is the low-voltage regulation and TP TC 020 the electromagnetic-compatibility one, so which number appears tells you what was assessed.

India

  • BIS

    Registration under India's Compulsory Registration Scheme, against an IS standard. IS 13252 is the Indian transposition of IEC 60950-1 and IS 15885 of IEC 61347, so the IS number identifies the product category.

    Covers only part of this series: except for 48V

Australia and New Zealand

  • RCMSupplier declaration

    The Regulatory Compliance Mark covers electrical safety and electromagnetic compatibility for Australia and New Zealand. It is applied by a registered local supplier against an AS/NZS standard, which is why the datasheet cites AS/NZS numbers alongside it.

An approval above is held by only some models in this series. The datasheet's own wording is quoted beside the mark; read it against this part number, and ask us for the certificate if your approval process needs it.

Isolation and electromagnetic compatibility
Withstand voltage I/P-O/P:4KVAC I/P-FG:2KVAC O/P-FG:1.25KVAC
Isolation resistance I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
EMC emission Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN55014, BS EN/EN61000-3-2 Class A(≤80% Load), BS EN/EN61000-3-3, BSMI CNS15936, EAC TP TC 020
EMC immunity Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN61000-6-2 (BS EN/EN50082-2),BS EN/EN55035, heavy industry level, EAC TP TC 020

Standards certified against

  • CNS15598-1
  • EN60335-1
  • EN61558-1/-2-16
  • EN62368-1
  • GB4943.1
  • IEC 60950-1
  • IEC60335-1
  • IEC61558-1
  • IEC61558-2-16
  • IEC62368-1
  • IS 13252
  • UL62368-1

Designed to reference

The datasheet lists these as design references. The series was built to them but has not been certified to them, so do not treat them as approvals.

AS/NZS 61558.1/2.16, AS/NZS62368.1

Read the datasheet's exact wording

CB: IEC62368-1, IEC61558-1, IEC61558-2-16, IEC60335-1 TUV: BS EN/EN62368-1, BS EN/EN61558-1/-2-16, BS EN/EN60335-1 UL: UL62368-1 CQC: GB4943.1 BSMI: CNS15598-1 EAC: TP TC 004, S/NZS62368.1(by CB) BIS: IS 13252(Part1):2010/IEC 60950-1:2005(except for 48V) RCM: Designed refer to AS/NZS 61558.1/2.16, AS/NZS62368.1

Reproduced unedited from the manufacturer's datasheet. Where an approval covers only some models, the wording says so. Ask us for the certificate itself if your approval process needs it.

Certificates

Certificate copy supplied with this model.
  • CE · R50453592

    100%
    CE certificate R50453592

    CE · Certificate number R50453592

Ordering & shipping information

Order and delivery terms
Part number LRS-100N2-24
Minimum order quantity 1
Country of origin China
Typical packed weight 525 g
Unit weight 350 g

LRS-100N2 model comparison

View all models
ModelOutput voltageRated currentRated powerPriceAvailability
LRS-100N2-4848 V2.1 A100.8 W$25.26
Ships in 3–5 business days
LRS-100N2-3636 V2.8 A100.8 W$25.26
Ships in 3–5 business days
LRS-100N2-24 Currently viewing24 V4.2 A100.8 W$23.37
Ships in 3–5 business days

LRS-100N2-24: 24 V output, 4.2 A; LRS-100N2-12: 12 V output, 8.5 A.

LRS-100N2-24: 24 V output, 4.2 A; LRS-100N2-36: 36 V output, 2.8 A.

LRS-100N2-24: 24 V output, 4.2 A; LRS-100N2-48: 48 V output, 2.1 A.

LRS-100N2-24: output adjustment range 21.6 to 28.8 V; LRS-100N2-12: 10.2 to 13.8 V; LRS-100N2-36: 32.4 to 39.6 V; LRS-100N2-48: 43.2 to 52.8 V.

Request a bulk quote

Tell us the quantity and target date and we will come back with pricing, lead time and stock position for this part number.

  1. 1 We confirm the part number and quantity against current stock.
  2. 2 You receive pricing, lead time and freight options by email.
  3. 3 Approve the quotation and we issue the invoice and shipping documents.

Request a quote for LRS-100N2-24

Confirm quantity and destination and we will come back with pricing and lead time.

Quoting LRS-100N2-24 View
Have a BOM? Reply to our confirmation email with the file attached.
We use your details only to answer this request.

Technical data source

Primary source
MEAN WELL
Datasheet revision
2025-04-07
Last verified

View the manufacturer datasheet How we source and verify product data

Specifications are transcribed from the manufacturer datasheet and are subject to change without notice. The current manufacturer datasheet governs in case of any discrepancy.