MEAN WELL Power Supplies for CCTV & Security Systems

Choose a supply for a CCTV or security system from the documented input of each device: its power type, voltage window and maximum current, including infrared illumination and heaters. Add up the current on each output, check the voltage that remains after cable loss, and decide early whether battery backup is required, because that changes the product type. On this page LRS-150-12 illustrates a plain 12V supply and PSC-60A a 13.8V supply with battery charger (UPS function). Neither is a PoE source, and nothing here approves either one for a specific camera, recorder or complete security system.

DC, AC and PoE Power in Security Installations

Start by writing down how each device is powered, because a security installation often mixes architectures. Some cameras and accessories take a DC input such as 12V or 24V, some take an AC input, and many are powered over Ethernet from a PoE switch or injector. The supplies discussed here, LRS-150-12 and PSC-60A, provide DC outputs only; they are not PoE sources and do not replace a PoE switch or injector.

Also decide where the supplies sit. A central supply in a cabinet feeds several devices through long cable runs, while local supplies near each group shorten the runs but add mains points. That choice drives both the load list and the cabling check, and it belongs to the system designer rather than to the supply.

  • DC-input devices: nominal voltage and accepted input window
  • AC-input devices: outside the scope of these DC supplies
  • PoE devices: powered by the PoE switch or injector, not by these supplies
  • Recorders and network switches with their own adapters: note whether they must share the backup

CCTV Load List: Night-Time Current and Accessories

List every device on each DC output with the maximum current from its own datasheet. For cameras, that is the figure with infrared illumination, heaters or motorised functions active, because night-time demand can exceed the daytime figure. Add every accessory that shares the output.

In this hypothetical case, 2.0A is about 16% of the 12.5A rating of LRS-150-12 and about 71% of the 2.8A CH1 rating of PSC-60A. The difference matters later: the backup-capable option has far less spare current, and its charging arrangement has to be confirmed before more devices are added.

Load worksheet (hypothetical example values)
Device Qty Maximum current each Total Source
12V DC camera, infrared on 4 0.5A 2.0A Camera datasheet (reader input)
Accessory on the same output - - - Accessory datasheet (reader input)
Total on one output - - 2.0A Calculated

Cable Voltage Drop and Backup Power for Cameras

Cable loss comes first. Voltage drop grows with current and cable length and is proportionally larger at 12V, so the far camera on a long run sees less than the supply output. LRS-150-12 lists an output voltage adjustment range of 10.2 ~ 13.8V, which can raise the set-point, but trimming does not replace cable sizing by the device maker's and installer's rules; the voltage-drop guide covers those checks.

Backup changes the product type. The LRS-150 specification lists no battery or backup function. The PSC-60 series is described as a single output with battery charger (UPS function): its suggested connection charges the battery and feeds the load while the mains is present, and the battery supplies the load when the mains fails. It also provides AC OK and battery-low signals as TTL open collector outputs, rated at a maximum of 30mA at 50VDC, which need an external voltage source.

Backup also changes the voltage the load sees. PSC-60A delivers 13.8V rather than 12V, and during backup the load runs from the battery, which PSC-60A cuts off at 10.5±0.5V; a device specified for 12V has to accept that whole range at its terminals. The required backup time, battery type and capacity come from the project specification, and this page does not estimate runtime.

LRS-150-12 vs PSC-60A for a 12V Camera Load

The matrix compares the two exact records against the hypothetical load. It records documented differences and open checks; it does not approve either model for a camera or a complete system.

Neither PDF makes a compatibility statement for cameras or recorders, and the PSC-60 page lists a PCB version and an enclosed type with different dimensions, so confirm which build an order refers to.

Catalog options compared for the hypothetical load
Check LRS-150-12 PSC-60A
Rated output 12V, 12.5A, 150W 13.8V; CH1 2.8A (range 0 ~ 4.3A), CH2 1.5A; 59.34W total
Typical efficiency 87.5% 84%
Input voltage 85 ~ 132VAC / 170 ~ 264VAC by switch 90 ~ 264VAC
Battery backup Not listed Battery charger with UPS function; battery cut-off 10.5±0.5V
Status signals Not listed AC OK and battery low, TTL open collector
Overload protection 110 ~ 140%, hiccup 105 ~ 150%, hiccup
Hypothetical 2.0A load About 16% of rated current About 71% of CH1 rated current
Working temperature -30 ~ +70℃ -20 ~ +70℃
Recorded decision Candidate where no backup is required Candidate where backup is required, after the load current, charging, battery and voltage window are confirmed

Equipment Details for a CCTV Power Check

Send the documented requirement instead of a target wattage, and the options can be checked against the exact PDFs.

Access-control, fire and egress functions carry their own requirements and approvals; they are handled on the access-control page rather than here.

  • Device list with power-input type, nominal voltage, accepted window and maximum current
  • Which devices share each output, with the cable length and type of each run
  • Whether backup is required, the required backup time and the planned battery
  • Whether AC OK or battery-low signals must be monitored, and by which equipment
  • Mounting location, ambient temperature and enclosure
  • Quantity and delivery destination

Frequently asked questions

Can a DC supply replace a PoE source?

No. A PoE device takes its power over the Ethernet cable from a PoE switch or injector. LRS-150-12 and PSC-60A provide DC outputs, and neither PDF describes PoE, so they do not replace a PoE source; at most they feed DC-input equipment whose own documents call for their output voltage.

Do cable losses affect the choice?

Yes. Voltage drop grows with current and length and is proportionally larger at 12V, so the load at the far end can see too little voltage even when the supply itself is correctly rated. Size the cabling to the device maker's and installer's rules and use the output adjustment only as a trim.

What changes when backup is required?

The product type changes from a plain supply to one with a battery charger and UPS function, such as PSC-60A. You then need the backup time, the battery type and capacity, and a load voltage window that covers the 13.8V output and the battery range down to the 10.5±0.5V cut-off, and you should decide whether the AC OK and battery-low signals will be monitored.

Information needed for a configuration check

  • Camera, recorder and accessory datasheets: power-input type, nominal voltage, accepted window and maximum current
  • Which devices share each output, with the cable length and type of each run
  • Required backup time and the planned battery type and capacity
  • Whether AC OK or battery-low signals will be monitored
  • Installation location, ambient temperature and enclosure

Manufacturer documents used