AC/DC Enclosed Type

LRS-150 Series

150 W enclosed switching supplies in a 199 × 98 × 30 mm case, convection cooled.

0 products

Products in this range are being added to the catalogue. Ask us for the part number you need in the meantime.

Browse all categories

Approvals and compliance

From the manufacturer's datasheet for this series

United States

  • UL

    UL Listing or Recognition means UL Solutions tested samples against the applicable UL safety standard and audits the factory that builds them. A UL file number is the usual evidence an inspector or specifier asks for in North America.

Europe

  • TÜV

    A TÜV certificate is third-party testing against the European EN standard. It is the evidence behind a CE declaration rather than a replacement for it: CE remains the manufacturer's own declaration, and the TÜV report is what makes that declaration defensible.

International

  • CB Scheme

    A CB Test Certificate reports testing against the IEC standard and is accepted by member certification bodies as the basis for a national approval. It shortens a new-country approval rather than granting market access by itself, so it is the most useful item on this list when you are entering a market that is not shown here.

Taiwan

  • BSMI

    Taiwan's mandatory inspection mark, issued against a CNS standard. CNS 15598-1 is the CNS transposition of IEC 62368-1, which is why the two numbers usually appear together.

Eurasian Economic Union

  • EAC

    Conformity with the Eurasian Economic Union technical regulations, covering Russia, Belarus, Kazakhstan, Armenia and Kyrgyzstan. TP TC 004 is the low-voltage regulation and TP TC 020 the electromagnetic-compatibility one, so which number appears tells you what was assessed.

India

  • BIS

    Registration under India's Compulsory Registration Scheme, against an IS standard. IS 13252 is the Indian transposition of IEC 60950-1 and IS 15885 of IEC 61347, so the IS number identifies the product category.

South Korea

  • KC

    Korea Certification, mandatory for electrical equipment in scope. The KC number mirrors the IEC standard it is based on, so KC 62368-1 is assessment against the Korean adoption of IEC 62368-1.

    Covers only part of this series: for LRS-150-12 only

Isolation and electromagnetic compatibility
Withstand voltage I/P-O/P:4KVAC I/P-FG:2KVAC O/P-FG:1.25KVAC
Isolation resistance I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
EMC emission Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN55014, BS EN/EN61000-3-2 Class A(≤75% Load), BS EN/EN61000-3-3,GB17625.1,GB/T 9254.1, BSMI CNS15936, EAC TP TC 020,KC KN32,KN35(for LRS-150-12 only)
EMC immunity Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN61000-6-2 (BS EN/EN50082-2),BS EN/EN55035, heavy industry level, EAC TP TC 020,KC KN32,KN35(for LRS-150-12 only)

Standards certified against

  • AS/NZS 62368.1
  • CNS15598-1
  • EN60335-1
  • EN61558-1/-2-16
  • EN62368-1
  • GB 4943.1
  • IEC 60950-1
  • IS13252
  • K60950-1
  • UL62368-1
Read the datasheet's exact wording

UL62368-1, TUV BS EN/EN62368-1, BS EN/EN60335-1, BS EN/EN61558-1/-2-16,GB 4943.1, BSMI CNS15598-1, EAC TP TC 004,KC K60950-1(for LRS-150-12 only), BIS IS13252(Part1): 2010/IEC 60950-1: 2005 , AS/NZS 62368.1(by CB) approved (datasheet note applies)

Reproduced unedited from the manufacturer's datasheet. Where an approval covers only some models, the wording says so. Ask us for the certificate itself if your approval process needs it.

Series FAQ

Do I need to derate this supply inside a sealed enclosure?

Yes. The published current rating assumes free air convection at 100 percent load up to 50 C. Inside a sealed enclosure the internal air sits above ambient, so size against the temperature at the supply, not the room.

Can two units be wired in parallel for more current?

Only where the datasheet lists a parallel function. Without it the units will not share load evenly and one will current-limit first.

What is the lead time on stocked part numbers?

Stocked part numbers ship within two business days. Anything not in stock is quoted with a firm date before the order is confirmed.

Still have a question?Ask a question

Request a bulk quote

Choosing between several models in this series? Send us the shortlist and we will come back with pricing, lead time and stock for each part number.

  1. 1 Tell us the models and quantities you are considering.
  2. 2 We confirm availability and send tiered pricing for the series.
  3. 3 Approve the quotation and we issue the invoice and shipping documents.