0-10V LED Dimming: Compatibility and Selection Guide
How 0-10V dimming works: sourcing vs sinking controllers, minimum dim level and dim-to-off, HLG-120H suffixes, wiring rules and a troubleshooting list.
An analog dimming control can only be checked against the exact driver interface. Confirm the model suffix and type first: only HLG-120H B-Type/AB-Type units and PWM-60 Blank-Type units carry the documented 3-in-1 analog input, while PWM-60 DA2-Type is a separate DALI-2 configuration. Then match the signal range (1~10VDC for HLG-120H B/AB-Type versus 0~10VDC for PWM-60 Blank-Type), the controller's current capability (100μA typ. sourced by HLG-120H B/AB-Type; 0.15mA per unit required by the PWM series), the documented minimum dimming and off behavior, and the wiring prohibitions before any connection. Check these against your own controller manual and LED load data, and have the installation reviewed by a qualified person.
0-10V Analog Dimming Control Interface
Analog dimming uses a separate low-voltage control input that is electrically distinct from both the mains input and the LED power output. In the HLG-120H manual, the 3-in-1 dimming interface applies to B-Type and AB-Type configurations only: the output current level is adjusted between DIM+ and DIM- using 1~10VDC, a 10V PWM signal in the frequency range 100Hz~3kHz, or resistance, with dimming curves plotted from about 10% output current at 1V to 100% at 10V.
The PWM-60 Blank-Type uses a similarly named DIM+/DIM- pair for 0~10VDC, a 10V PWM signal in the frequency range 100Hz~3kHz, or resistance, with a documented dimming range of 0~100%. The PWM-60 output itself is PWM style, at 1.47kHz (typ.) for Blank-Type and 2.5kHz (typ.) for DA2-Type, with dimming achieved by varying the duty cycle of the output current. The DA2-Type instead exposes DA+/DA- for a DALI signal and is a separate configuration.
The documented input ranges are not identical: 1~10VDC for HLG-120H B/AB-Type versus 0~10VDC for PWM-60 Blank-Type. A controller described generically as “0-10V” therefore cannot be assumed to suit either driver without checking both the controller manual and the exact driver datasheet.
Current Sourcing vs Sinking and Compatible 0-10V Controllers
In this analog scheme the driver sources a small current on its dimming input and the controller must be able to sink it. The HLG-120H B/AB-Type dimming documentation lists a dimming source current from the power supply of 100μA (typ.) and suggests direct connection to LEDs rather than use with additional drivers.
For the PWM-60, the installation manual makes the check explicit: for dimmable LED drivers, make sure the dimming controller is capable of driving these units, and the manual states that the PWM series require 0.15mA per unit.
As an explicitly hypothetical illustration only: if a controller datasheet specified a sink capability of 10mA across all connected dimming inputs, and each HLG-120H B/AB-Type input sources 100μA (typ.), the arithmetic would be 10mA ÷ 0.1mA = 100 driver inputs. This is illustrative arithmetic on documented typical values, not a measured system, a wiring instruction, or a design margin; the actual controller limit must come from the controller manufacturer's own installation manual.
Permitted controller models, sink behavior and isolation details must be verified from the controller manufacturer's own documentation; this guide does not assert compatibility with any specific controller, dimmer, LED module or strip.
Minimum Dimming Level and Dim-to-Off Behavior
Minimum brightness and off behavior are model-specific and cannot be generalized from one document to another. In particular, 0Vdc at the analog input does not always switch the lamp off: for HLG-120H B-Type, the datasheet shows a switch-and-relay configuration as the way to turn the lighting fixture down to 0% brightness, while for PWM-60 Blank-Type the documented behavior includes a deadband between 0% and 6% duty cycle where the output current is not defined. That document does not establish AB-Type dim-to-off behavior; verify the exact AB-Type manual before specifying an off method.
| Exact configuration | Documented control input | Documented minimum and off behavior |
|---|---|---|
| HLG-120H B-Type | 1~10VDC, 10V PWM signal (100Hz~3kHz), or resistance between DIM+ and DIM- | Curves plotted from about 10% output current at 1V to 100% at 10V; the manual shows a switch-and-relay configuration for turning the fixture down to 0% brightness |
| PWM-60 Blank-Type | 0~10VDC, 10V PWM signal (100Hz~3kHz), or resistance between DIM+ and DIM- | Dimming range 0~100%; minimum duty cycle of output current about 6%, output current not defined between 0% and 6%; duty cycle can drop to 0% at about 0kΩ or 0Vdc, or a 10V PWM signal with 0% duty cycle |
| PWM-60 DA2-Type | DALI signal between DA+ and DA- | First step fixed at 0.2% of output; specification lists minimum dimming level 0.2% for the DALI-2 type |
HLG-120H and PWM-60 Suffixes That Set the Dimming Interface
The suffix, not the series name, determines the interface. The electrical ratings cited in this guide come from the exact HLG-120H-24 and PWM-60-24 datasheet records, while the dimming interface applies only to the suffixes documented below; the unsuffixed HLG-120H-24 record must not be assumed to carry the B/AB-Type dimming interface.
- HLG-120H Blank type: fixed output.
- HLG-120H A-Type: built-in potentiometer adjustment.
- HLG-120H B-Type: documented 3-in-1 dimming interface.
- HLG-120H AB-Type: potentiometer adjustment plus documented 3-in-1 dimming.
- HLG-120H D-Type: timer-dimming type; consult the manufacturer documentation.
- PWM-60 Blank-Type and DA2-Type are separate analog and DALI configurations.
0-10V Control Wiring Rules from the Manual
Control wiring must follow the exact drawings in the applicable manual, and the manuals include hard prohibitions: the HLG-120H dimming pages state “DO NOT connect DIM- to -V” for each of the three additive methods, and the PWM-60 documentation states “DO NOT connect DIM- to Vo-” for its 0~10VDC, 10V PWM and resistance methods. The manuals show DIM+ as a purple wire and DIM- as a pink wire on the HLG-120H B/AB-Type dimming pages and on the PWM-60 Blank-Type.
For 0% brightness on HLG-120H B-Type, the datasheet illustrates a switch-and-relay configuration that can turn the lighting fixture ON/OFF, rather than relying on the analog input alone. Do not extend that behavior to AB-Type without checking the exact AB-Type manual. The PWM-60 installation manual also instructs that before any installation or maintenance work the power supply be disconnected from the utility and secured so it cannot be reconnected inadvertently.
All interface wiring and any mains-side connection require qualified review; this guide does not provide energized wiring instructions and does not prescribe any universal design margin.
- Do not connect DIM- to -V on HLG-120H B/AB-Type units (documented prohibition).
- Do not connect DIM- to Vo- on PWM-60 Blank-Type units (documented prohibition).
- For 0% brightness on HLG-120H B-Type, follow the manual's switch-and-relay configuration instead of assuming the analog input provides it.
- Disconnect the supply from the utility before installation or maintenance and secure against inadvertent reconnection, per the PWM-60 manual.
- Route separation, cable ratings and IP-rated connections must follow the applicable manual; do not infer shared grounding between control and output terminals.
0-10V Dimming Troubleshooting Checklist
Most analog-dimming problems trace back to a mismatch between what the controller outputs and what the exact driver type accepts. Work through the checklist below on paper before touching any wiring, and stop before any live testing or energized work, which must be left to qualified personnel.
- Record the controller's documented output signal range and sink-current capability from its own manual.
- Record the driver's exact model number and suffix/type from the label, plus its documented input range and required per-unit current (100μA typ. sourced for HLG-120H B/AB-Type; 0.15mA per unit for the PWM series).
- Record the LED module or strip rated voltage and current and the total connected load per driver.
- Confirm the wiring plan against the exact manual drawings, including the DIM- to -V / Vo- prohibitions.
- Confirm the required minimum brightness and off behavior against the documented curves and table above.
- If any item cannot be documented, request the missing datasheet rather than testing on energized equipment.
Shortlisting Exact 0-10V Driver Models
Where the documented interface matches the application, procurement can shortlist exact MPNs rather than series names. The ratings in this guide come from the HLG-120H-24 record (24V rated output, 5A rated current, 120W rated power, 93% typical efficiency, 150mVp-p ripple and noise) and the PWM-60-24 record (24V, 2.5A, 60W, 89% typical efficiency), each per its own datasheet. The dimming interface still depends on the suffix/type, so the suffix must be specified on the order.
Quote requests should state the controller model, the LED load data, and the required dimming range and off behavior so the exact suffix can be confirmed against documentation before purchase.
Frequently asked questions
Does 0V always switch the lamp off?
No, and the behavior differs by exact configuration. For HLG-120H B-Type, the datasheet shows that turning the lighting fixture down to 0% brightness uses the illustrated switch-and-relay configuration rather than the analog input alone; that document does not establish equivalent dim-to-off behavior for AB-Type. On PWM-60 Blank-Type, the duty cycle can drop to 0% at about 0kΩ or 0Vdc, but the minimum duty cycle of output current is about 6% and the output current is not defined between 0% and 6%. Verify the exact type manual instead of assuming a universal dim-to-off behavior.
Can a 1-10V controller be used?
It depends on the exact driver input range and the controller's sink capability. The HLG-120H B/AB-Type interface is documented for 1~10VDC, while the PWM-60 Blank-Type interface is documented for 0~10VDC, so the two are not documented as interchangeable. The driver-side currents are also specific: 100μA (typ.) sourced on the HLG-120H B/AB-Type input and 0.15mA per unit required by the PWM series. The controller's own installation manual must confirm its signal range and sink capability; this guide cannot assert compatibility with any specific controller.
Does every HLG or XLG suffix support this method?
No. The HLG-120H model encoding assigns the documented 3-in-1 analog interface to B-Type and AB-Type; the other listed types have different functions. This guide does not cover XLG documentation, so check the exact XLG datasheet before assuming any interface.
Information needed for a configuration check
- Controller/dimmer manufacturer installation manual stating its documented signal range and sink-current capability.
- Exact model number with suffix/type from the installed or candidate driver label (for example, whether the HLG-120H unit is B-Type or AB-Type).
- LED module or strip rated voltage and current per unit, and the total connected load per driver.
- Whether dim-to-off is a requirement for the application, and any switch/relay arrangement already planned.
- Installation environment details (indoor/outdoor, mounting) needed for the IP-rating and ventilation review.
Manufacturer documents used
- HLG-120H-SPEC.PDF, consulted pages 1, 4, 5
- PWM-60-spec.pdf, consulted pages 1, 2, 3, 4, 8