MEAN WELL UHP-200A-4.5 180W 4.5V 40A Enclosed Type

Part numberUHP-200A-4.5
Output voltage 4.5 V
Rated current 40 A
Rated power 180 W
$71.06Excluding tax and shipping
Ships in 3–5 business daysLead time is the time from order to dispatch, and does not include transit time.
Request bulk quote

Procurement confidence

  • Genuine product Sourced through our documented supply chain.
  • Worldwide shipping Export documentation handled for you.
  • Commercial invoice Available for every order.
  • Specification support Talk to someone who reads datasheets.
Output
Output voltage 4.5 V
Rated current 40 A
Rated power 180 W
AC input range 90–264 VAC
Typical efficiency 88 %
Mechanical
Operating temperature -30 to 70 °C
Power factor correction Supported
Dimensions (L × W × H) 167 × 55 × 26 mm

Is this model right for you?

Within the UHP-200A series, the three models differ by output voltage, output adjustment range, and rated power. UHP-200A-4.2 provides 4.2 V and 168 W; UHP-200A-4.5 provides 4.5 V and 180 W; UHP-200A-5 provides 5 V and 200 W. Output adjustment ranges are 4.0~4.4V, 4.3~4.7V, and 4.7~5.3V respectively.

Product overview

The UHP-200A-4.5 provides a 4.5 V output with 40 A output current and 180 W rated power. The output adjustment range is 4.3~4.7V, and typical efficiency is 88%. The input voltage range is 90 ~ 264VAC 127 ~ 370VDC with a frequency range of 47 ~ 63Hz. Ripple and noise are 200mVp-p. Dimensions are 167 × 55 × 26 mm and net weight is 420 g.

Where this model fits

The UHP-200A-4.5 is used in Industrial Automation and Test & Measurement. Its operating temperature range is -30 to 70 °C, humidity range is 20 to 95%, and net weight is 420 g. Dimensions are 167 × 55 × 26 mm.

Complete technical specifications

Rev. 2024-11-23
Output
Output voltage 4.5 V
Rated current 40 A
Rated power 180 W
Voltage adjustment range 4.3–4.7 V
Ripple & noise 200 mVp-p
Input
AC input range 90–264 VAC
DC input range 127–370 VDC
Frequency range 47–63 Hz
Typical efficiency 88 %
Power factor 0.97
Power factor correction Supported
Protection
Over voltage Protected
Over temperature Protected
Hiccup mode, recovers automatically after fault condition is removed
Environmental
Operating temperature -30 to 70 °C
Storage temperature -40 to 85 °C
Operating humidity 20–95 % RH
Vibration 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
Mechanical
Dimensions (L × W × H) 167 × 55 × 26 mm
Net weight 420.0 g
Safety & compliance
Safety standards UL 62368-1,TUV BS EN/EN62368-1,GB 4943.1, EAC TP TC 004 approved

These approvals are recorded for the series as a whole. Where a line names particular models or ratings, it applies only to those — read it against this part number, and ask us for the certificate if your approval process needs it.

Identification
Part number UHP-200A-4.5
Brand MEAN WELL
Category AC/DC Enclosed Type
Series UHP-200A

Approvals and compliance

From the manufacturer's datasheet for this series

United States

  • UL

    UL Listing or Recognition means UL Solutions tested samples against the applicable UL safety standard and audits the factory that builds them. A UL file number is the usual evidence an inspector or specifier asks for in North America.

Europe

  • TÜV

    A TÜV certificate is third-party testing against the European EN standard. It is the evidence behind a CE declaration rather than a replacement for it: CE remains the manufacturer's own declaration, and the TÜV report is what makes that declaration defensible.

Eurasian Economic Union

  • EAC

    Conformity with the Eurasian Economic Union technical regulations, covering Russia, Belarus, Kazakhstan, Armenia and Kyrgyzstan. TP TC 004 is the low-voltage regulation and TP TC 020 the electromagnetic-compatibility one, so which number appears tells you what was assessed.

Isolation and electromagnetic compatibility
Withstand voltage I/P-O/P:3.0KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
Isolation resistance I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC/25℃/ 70%RH
EMC emission Compliance to BS EN/EN55032 (CISPR32),GB17625.1,GB/T 9254.1, BS EN/EN61000-3-2,-3,EAC TP TC 020
EMC immunity Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11;BS EN/EN55035, light industry level (surge 4KV),EAC TP TC 020

Standards certified against

  • EN62368-1
  • GB 4943.1
  • UL 62368-1
Read the datasheet's exact wording

UL 62368-1,TUV BS EN/EN62368-1,GB 4943.1, EAC TP TC 004 approved

Reproduced unedited from the manufacturer's datasheet. Where an approval covers only some models, the wording says so. Ask us for the certificate itself if your approval process needs it.

Certificates

Certificate copy supplied with this model.
  • CE · R50453592

    100%
    CE certificate R50453592

    CE · Certificate number R50453592

Ordering & shipping information

Order and delivery terms
Part number UHP-200A-4.5
Minimum order quantity 1
Country of origin China
Typical packed weight 720 g
Unit weight 420 g

UHP-200A model comparison

View all models
ModelOutput voltageRated currentRated powerPriceAvailability
UHP-200A-55 V40 A200 W$71.06
Ships in 3–5 business days
UHP-200A-4.24.2 V40 A168 W$71.06
Ships in 3–5 business days
UHP-200A-4.5 Currently viewing4.5 V40 A180 W$71.06
Ships in 3–5 business days

UHP-200A-4.5 provides 4.5 V output; UHP-200A-4.2 provides 4.2 V output.

UHP-200A-4.5 provides 180 W rated power; UHP-200A-4.2 provides 168 W rated power.

UHP-200A-4.5 provides 4.5 V output; UHP-200A-5 provides 5 V output.

UHP-200A-4.5 provides 180 W rated power; UHP-200A-5 provides 200 W rated power.

Request a bulk quote

Tell us the quantity and target date and we will come back with pricing, lead time and stock position for this part number.

  1. 1 We confirm the part number and quantity against current stock.
  2. 2 You receive pricing, lead time and freight options by email.
  3. 3 Approve the quotation and we issue the invoice and shipping documents.

Request a quote for UHP-200A-4.5

Confirm quantity and destination and we will come back with pricing and lead time.

Quoting UHP-200A-4.5 View
Have a BOM? Reply to our confirmation email with the file attached.
We use your details only to answer this request.

Technical data source

Primary source
MEAN WELL
Datasheet revision
2024-11-23
Last verified

How we source and verify product data

Specifications are transcribed from the manufacturer datasheet and are subject to change without notice. The current manufacturer datasheet governs in case of any discrepancy.