MEAN WELL RPS-60-5 50W 5V 10A Open Frame

Part numberRPS-60-5
Output voltage 5 V
Rated current 10 A
Rated power 50 W
$21.79Excluding tax and shipping
Ships in 3–5 business daysLead time is the time from order to dispatch, and does not include transit time.
Request bulk quote

Procurement confidence

  • Genuine product Sourced through our documented supply chain.
  • Worldwide shipping Export documentation handled for you.
  • Commercial invoice Available for every order.
  • Specification support Talk to someone who reads datasheets.
Output
Output voltage 5 V
Rated current 10 A
Rated power 50 W
AC input range 90–264 VAC
Typical efficiency 79 %
Mechanical
Cooling Free-air convection
Operating temperature -20 to 70 °C
Dimensions (L × W × H) 101.6 × 50.8 × 29 mm

Is this model right for you?

Within the RPS-60 series, the RPS-60-5 differs from siblings by output voltage, output current, rated power, efficiency, and adjustment range. RPS-60-5: 5 V, 10 A, 50 W, 79%, 4.75 ~ 5.5V. RPS-60-12: 12 V, 5 A, 60 W, 84%, 11.4 ~ 13.2V. RPS-60-24: 24 V, 2.5 A, 60 W, 87%, 22.8 ~ 27.6V.

Product overview

The RPS-60-5 provides a 5 V output at 10 A with 50 W rated power. The output adjustment range is 4.75 ~ 5.5V, ripple and noise is 60mVp-p, and typical efficiency is 79%. Input frequency range is 47 ~ 63Hz. Dimensions are 101.6 × 50.8 × 29 mm and net weight is 150 g.

Where this model fits

The RPS-60-5 is used in Embedded & Board-level Design. Its 5 V output at 10 A and 50 W rated power suit board-level power conversion. The 101.6 × 50.8 × 29 mm dimensions and 150 g net weight describe the package for enclosure integration.

Complete technical specifications

Rev. 2026-02-28
Output
Output voltage 5 V
Rated current 10 A
Rated power 50 W
Voltage adjustment range 4.75–5.5 V
Ripple & noise 60 mVp-p
Input
AC input range 90–264 VAC
DC input range 127–370 VDC
Frequency range 47–63 Hz
Typical efficiency 79 %
Environmental
Operating temperature -20 to 70 °C
Storage temperature -40 to 85 °C
Operating humidity 20–90 % RH
Vibration 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
Mechanical
Dimensions (L × W × H) 101.6 × 50.8 × 29 mm
Net weight 150.0 g
Cooling Free-air convection
Fan Not supported
Safety & compliance
Safety standards CAN/CSA C22.2 No. 60601-1:2014+A2, IEC 62368-1:2014, UL 62368-1, 2nd Ed, CSA C22.2 No. 62368-1-14, 2nd Ed

These approvals are recorded for the series as a whole. Where a line names particular models or ratings, it applies only to those — read it against this part number, and ask us for the certificate if your approval process needs it.

Identification
Part number RPS-60-5
Brand MEAN WELL
Category AC/DC Open Frame
Series RPS-60

Approvals and compliance

From the manufacturer's datasheet for this series
Isolation and electromagnetic compatibility
Withstand voltage I/P-O/P:4KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC
EMC emission Parameter Standard Test Level / Note

Standards certified against

  • IEC 62368-1
  • UL 62368-1
Read the datasheet's exact wording

CAN/CSA C22.2 No. 60601-1:2014+A2, IEC 62368-1:2014, UL 62368-1, 2nd Ed, CSA C22.2 No. 62368-1-14, 2nd Ed

Reproduced unedited from the manufacturer's datasheet. Where an approval covers only some models, the wording says so. Ask us for the certificate itself if your approval process needs it.

Certificates

Certificate copy supplied with this model.
  • CE · R50453592

    100%
    CE certificate R50453592

    CE · Certificate number R50453592

Ordering & shipping information

Order and delivery terms
Part number RPS-60-5
Minimum order quantity 1
Country of origin China
Typical packed weight 310 g
Unit weight 150 g

RPS-60 model comparison

View all models
ModelOutput voltageRated currentRated powerPriceAvailability
RPS-60-5 Currently viewing5 V10 A50 W$21.79
Ships in 3–5 business days
RPS-60-1212 V5 A60 W$21.79
Ships in 3–5 business days

RPS-60-5 lists 5 V output and 10 A output current; RPS-60-12 lists 12 V output and 5 A output current.

RPS-60-5 lists 50 W rated power; RPS-60-12 lists 60 W rated power.

RPS-60-5 lists 79% typical efficiency; RPS-60-24 lists 87% typical efficiency.

RPS-60-5 lists 60mVp-p ripple and noise; RPS-60-15 lists 100mVp-p ripple and noise.

Request a bulk quote

Tell us the quantity and target date and we will come back with pricing, lead time and stock position for this part number.

  1. 1 We confirm the part number and quantity against current stock.
  2. 2 You receive pricing, lead time and freight options by email.
  3. 3 Approve the quotation and we issue the invoice and shipping documents.

Request a quote for RPS-60-5

Confirm quantity and destination and we will come back with pricing and lead time.

Quoting RPS-60-5 View
Have a BOM? Reply to our confirmation email with the file attached.
We use your details only to answer this request.

Technical data source

Primary source
MEAN WELL
Datasheet revision
2026-02-28
Last verified

View the manufacturer datasheet How we source and verify product data

Specifications are transcribed from the manufacturer datasheet and are subject to change without notice. The current manufacturer datasheet governs in case of any discrepancy.