MEAN WELL RCB-1600-48 1584W 57.6V 27.5A Rack Power

Part numberRCB-1600-48
Output voltage 57.6 V
Rated current 27.5 A
Rated power 1584 W
$451.54Excluding tax and shipping
Ships in 3–5 business daysLead time is the time from order to dispatch, and does not include transit time.
Request bulk quote

Procurement confidence

  • Genuine product Sourced through our documented supply chain.
  • Worldwide shipping Export documentation handled for you.
  • Commercial invoice Available for every order.
  • Specification support Talk to someone who reads datasheets.
Output
Output voltage 57.6 V
Rated current 27.5 A
Rated power 1584 W
AC input range 90–264 VAC
Typical efficiency 93 %
Mechanical
Operating temperature -30 to 70 °C
Power factor correction Supported
Dimensions (L × W × H) 300 × 85 × 41 mm

Is this model right for you?

Within the RCB-1600 Series, the RCB-1600-48 differs from the RCB-1600-12 and RCB-1600-24 by output adjustment range and rated power. RCB-1600-48: 47.5 ~ 58.8V, 1584 W; RCB-1600-24: 23.5 ~ 30V; RCB-1600-12: 11.5 ~ 15V, 1440 W.

Product overview

The RCB-1600-48 provides a rated power of 1584 W with a typical efficiency of 93%. Its input voltage range is 90 ~ 264VAC 250 ~ 370VDC at 47 ~ 63Hz. The output adjustment range is 47.5 ~ 58.8V. Dimensions are 300 × 85 × 41 mm and net weight is 1870 g.

Where this model fits

The RCB-1600-48 is used in Telecom & Datacom applications. Its operating temperature range is -30 to 70 °C and its humidity range is 20 to 90%. The product measures 300 × 85 × 41 mm and weighs 1870 g.

Complete technical specifications

Rev. 2025-10-23
Output
Output voltage 57.6 V
Rated current 27.5 A
Rated power 1584 W
Voltage adjustment range 47.5–58.8 V
Input
AC input range 90–264 VAC
DC input range 250–370 VDC
Frequency range 47–63 Hz
Typical efficiency 93 %
Power factor 0.97
Power factor correction Supported
Protection
Over temperature Protected
Environmental
Operating temperature -30 to 70 °C
Storage temperature -40 to 85 °C
Operating humidity 20–90 % RH
Vibration 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
Mechanical
Dimensions (L × W × H) 300 × 85 × 41 mm
Net weight 1870.0 g
Safety & compliance
Safety standards UL62368-1, TUV BS EN/EN62368-1, EAC TP TC 004 approved

These approvals are recorded for the series as a whole. Where a line names particular models or ratings, it applies only to those — read it against this part number, and ask us for the certificate if your approval process needs it.

Identification
Part number RCB-1600-48
Brand MEAN WELL
Category AC/DC Rack Power
Series RCB-1600

Approvals and compliance

From the manufacturer's datasheet for this series

United States

  • UL

    UL Listing or Recognition means UL Solutions tested samples against the applicable UL safety standard and audits the factory that builds them. A UL file number is the usual evidence an inspector or specifier asks for in North America.

Europe

  • TÜV

    A TÜV certificate is third-party testing against the European EN standard. It is the evidence behind a CE declaration rather than a replacement for it: CE remains the manufacturer's own declaration, and the TÜV report is what makes that declaration defensible.

Eurasian Economic Union

  • EAC

    Conformity with the Eurasian Economic Union technical regulations, covering Russia, Belarus, Kazakhstan, Armenia and Kyrgyzstan. TP TC 004 is the low-voltage regulation and TP TC 020 the electromagnetic-compatibility one, so which number appears tells you what was assessed.

Isolation and electromagnetic compatibility
Withstand voltage I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC (0.5KVAC for 12V)
EMC emission Compliance to BS EN/EN55032 (CISPR32) Conduction Class B, Radiation Class A ; BS EN/EN61000-3-2,-3, EAC TP TC 020
EMC immunity Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, EAC TP TC 020

Standards certified against

  • EN62368-1
  • UL62368-1
Read the datasheet's exact wording

UL62368-1, TUV BS EN/EN62368-1, EAC TP TC 004 approved

Reproduced unedited from the manufacturer's datasheet. Where an approval covers only some models, the wording says so. Ask us for the certificate itself if your approval process needs it.

Certificates

Certificate copy supplied with this model.
  • CE · R50453592

    100%
    CE certificate R50453592

    CE · Certificate number R50453592

Ordering & shipping information

Order and delivery terms
Part number RCB-1600-48
Minimum order quantity 1
Country of origin China
Typical packed weight 2242 g
Unit weight 1870 g

RCB-1600 model comparison

View all models
ModelOutput voltageRated currentRated powerPriceAvailability
RCB-1600-1212 V100 A1440 W$451.54
Ships in 3–5 business days
RCB-1600-48 Currently viewing57.6 V27.5 A1584 W$451.54
Ships in 3–5 business days
RCB-1600-2428.8 V55 A1584 W$451.54
Ships in 3–5 business days

RCB-1600-48 lists an output adjustment range of 47.5 ~ 58.8V, while RCB-1600-24 lists 23.5 ~ 30V.

RCB-1600-48 lists an output adjustment range of 47.5 ~ 58.8V, while RCB-1600-12 lists 11.5 ~ 15V.

RCB-1600-48 lists a rated power of 1584 W, while RCB-1600-12 lists 1440 W.

RCB-1600-48 lists a typical efficiency of 93%, while RCB-1600-12 lists 90.5%.

Request a bulk quote

Tell us the quantity and target date and we will come back with pricing, lead time and stock position for this part number.

  1. 1 We confirm the part number and quantity against current stock.
  2. 2 You receive pricing, lead time and freight options by email.
  3. 3 Approve the quotation and we issue the invoice and shipping documents.

Request a quote for RCB-1600-48

Confirm quantity and destination and we will come back with pricing and lead time.

Quoting RCB-1600-48 View
Have a BOM? Reply to our confirmation email with the file attached.
We use your details only to answer this request.

Technical data source

Primary source
MEAN WELL
Datasheet revision
2025-10-23
Last verified

How we source and verify product data

Specifications are transcribed from the manufacturer datasheet and are subject to change without notice. The current manufacturer datasheet governs in case of any discrepancy.