MEAN WELL MDR-60-12 60W 12V 5A DIN Rail

Part numberMDR-60-12
Output voltage 12 V
Rated current 5 A
Rated power 60 W
$30.32Excluding tax and shipping
Ships in 3–5 business daysLead time is the time from order to dispatch, and does not include transit time.
Request bulk quote

Procurement confidence

  • Genuine product Sourced through our documented supply chain.
  • Worldwide shipping Export documentation handled for you.
  • Commercial invoice Available for every order.
  • Specification support Talk to someone who reads datasheets.
Output
Output voltage 12 V
Rated current 5 A
Rated power 60 W
AC input range 85–264 VAC
Typical efficiency 85 %
Mechanical
Operating temperature -20 to 70 °C
Dimensions (L × W × H) 40 × 90 × 100 mm

Is this model right for you?

Within the MDR-60 series, the MDR-60-12 differs from siblings by output voltage and current. MDR-60-12: 12 V, 5 A; MDR-60-5: 5 V, 10 A; MDR-60-24: 24 V, 2.5 A; MDR-60-48: 48 V, 1.25 A. Rated power is 60 W for MDR-60-12, MDR-60-24, and MDR-60-48, while MDR-60-5 is 50 W.

Product overview

The MDR-60-12 provides a 12 V output with 5 A output current and 60 W rated power. The output adjustment range is 12 ~ 15V, and typical efficiency is 85%. Ripple and noise are 120mVp-p. The input voltage range is 85 ~ 264VAC 120 ~ 370VDC at 47 ~ 63Hz. Dimensions are 40 × 90 × 100 mm and net weight is 287 g.

Where this model fits

The MDR-60-12 is used in Industrial Automation, Motor Drives, and Building & Home Automation. Its operating temperature range is -20 to 70 °C, humidity range is 20 to 90%, and net weight is 287 g. Dimensions are 40 × 90 × 100 mm.

Complete technical specifications

Rev. 2025-07-25
Output
Output voltage 12 V
Rated current 5 A
Rated power 60 W
Voltage adjustment range 12–15 V
Ripple & noise 120 mVp-p
Input
AC input range 85–264 VAC
DC input range 120–370 VDC
Frequency range 47–63 Hz
Typical efficiency 85 %
Environmental
Operating temperature -20 to 70 °C
Storage temperature -40 to 85 °C
Operating humidity 20–90 % RH
Vibration Component : 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes ; Mounting : Compliance to IEC60068-2-6
Mechanical
Dimensions (L × W × H) 40 × 90 × 100 mm
Net weight 287.0 g
Safety & compliance
Safety standards UL508, UL62368-1, TUV BS EN/EN62368-1,Class I, Div. 2 Group A, B, C, D Hazardous Locations T4, EAC TP TC 004, BSMI CNS14336-1, AS/NZS 60950.1 , BIS IS13252(Part1): 2010/IEC 60950-1:2005(except 48V) approved

These approvals are recorded for the series as a whole. Where a line names particular models or ratings, it applies only to those — read it against this part number, and ask us for the certificate if your approval process needs it.

Identification
Part number MDR-60-12
Brand MEAN WELL
Category AC/DC DIN Rail
Series MDR-60

Approvals and compliance

From the manufacturer's datasheet for this series

United States

  • UL

    UL Listing or Recognition means UL Solutions tested samples against the applicable UL safety standard and audits the factory that builds them. A UL file number is the usual evidence an inspector or specifier asks for in North America.

Europe

  • TÜV

    A TÜV certificate is third-party testing against the European EN standard. It is the evidence behind a CE declaration rather than a replacement for it: CE remains the manufacturer's own declaration, and the TÜV report is what makes that declaration defensible.

Taiwan

  • BSMI

    Taiwan's mandatory inspection mark, issued against a CNS standard. CNS 15598-1 is the CNS transposition of IEC 62368-1, which is why the two numbers usually appear together.

Eurasian Economic Union

  • EAC

    Conformity with the Eurasian Economic Union technical regulations, covering Russia, Belarus, Kazakhstan, Armenia and Kyrgyzstan. TP TC 004 is the low-voltage regulation and TP TC 020 the electromagnetic-compatibility one, so which number appears tells you what was assessed.

India

  • BIS

    Registration under India's Compulsory Registration Scheme, against an IS standard. IS 13252 is the Indian transposition of IEC 60950-1 and IS 15885 of IEC 61347, so the IS number identifies the product category.

Isolation and electromagnetic compatibility
Withstand voltage I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
Isolation resistance I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500VDC / 25℃/ 70% RH
EMC emission Compliance to BS EN/EN55032 (CISPR32), BS EN/EN61204-3 Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020, CNS13438 Class B
EMC immunity Compliance to BS EN/EN61000-4-2, 3, 4, 5, 6, 8, 11, BS EN/EN55035, BS EN/EN61000-6-2, BS EN/EN61204-3, heavy industry level, EAC TP TC 020

Standards certified against

  • AS/NZS 60950.1
  • CNS14336-1
  • EN62368-1
  • IEC 60950-1
  • IS13252
  • UL62368-1
Read the datasheet's exact wording

UL508, UL62368-1, TUV BS EN/EN62368-1,Class I, Div. 2 Group A, B, C, D Hazardous Locations T4, EAC TP TC 004, BSMI CNS14336-1, AS/NZS 60950.1 , BIS IS13252(Part1): 2010/IEC 60950-1:2005(except 48V) approved

Reproduced unedited from the manufacturer's datasheet. Where an approval covers only some models, the wording says so. Ask us for the certificate itself if your approval process needs it.

Certificates

Certificate copy supplied with this model.
  • CE · R50453592

    100%
    CE certificate R50453592

    CE · Certificate number R50453592

Ordering & shipping information

Order and delivery terms
Part number MDR-60-12
Minimum order quantity 1
Country of origin China
Typical packed weight 461 g
Unit weight 287 g

MDR-60 model comparison

View all models
ModelOutput voltageRated currentRated powerPriceAvailability
MDR-60-12 Currently viewing12 V5 A60 W$30.32
Ships in 3–5 business days
MDR-60-4848 V1.25 A60 W$30.32
Ships in 3–5 business days
MDR-60-2424 V2.5 A60 W$28.11
Ships in 3–5 business days

MDR-60-12 provides 12 V and 5 A; MDR-60-5 provides 5 V and 10 A.

MDR-60-12 provides 12 V and 5 A; MDR-60-24 provides 24 V and 2.5 A.

MDR-60-12 provides 12 V and 5 A; MDR-60-48 provides 48 V and 1.25 A.

MDR-60-12 rated power is 60 W; MDR-60-5 rated power is 50 W.

Request a bulk quote

Tell us the quantity and target date and we will come back with pricing, lead time and stock position for this part number.

  1. 1 We confirm the part number and quantity against current stock.
  2. 2 You receive pricing, lead time and freight options by email.
  3. 3 Approve the quotation and we issue the invoice and shipping documents.

Request a quote for MDR-60-12

Confirm quantity and destination and we will come back with pricing and lead time.

Quoting MDR-60-12 View
Have a BOM? Reply to our confirmation email with the file attached.
We use your details only to answer this request.

Technical data source

Primary source
MEAN WELL
Datasheet revision
2025-07-25
Last verified

View the manufacturer datasheet How we source and verify product data

Specifications are transcribed from the manufacturer datasheet and are subject to change without notice. The current manufacturer datasheet governs in case of any discrepancy.