MEAN WELL LCM-40KN 42W 2-100V to 2-40V, 6 levels KNX

Part numberLCM-40KN
Output voltage 2-100V to 2-40V, 6 levels
Rated current 350mA / 500mA / 600mA / 700mA / 900mA / 1050mA
Rated power42 W
$51.92Excluding tax and shipping
Ships in 3–5 business daysLead time is the time from order to dispatch, and does not include transit time.
Request bulk quote

Procurement confidence

  • Genuine product Sourced through our documented supply chain.
  • Worldwide shipping Export documentation handled for you.
  • Commercial invoice Available for every order.
  • Specification support Talk to someone who reads datasheets.
Output
Rated power 42 W
Output voltage 2-100V to 2-40V, 6 levels
Rated current 350mA / 500mA / 600mA / 700mA / 900mA / 1050mA
AC input range 180–295 VAC
Number of outputs 6
Mechanical
Operating temperature -30 to 90 °C
Power factor correction Supported
Dimensions (L × W × H) 123.5 × 81.5 × 23 mm

Is this model right for you?

The LCM-40KN is the only model in the LCM-40KN series. It lists 180 ~ 295VAC 220 ~ 392VDC (referenced datasheet operating conditions apply) input.

Product overview

The LCM-40KN belongs to the MEAN WELL KNX LED Driver family and is classified as an AC/DC KNX product. Its dimensions are 123.5 × 81.5 × 23 mm and its net weight is 240 g. The input frequency range is 47 ~ 63Hz. Operating temperature spans -30 to 90 °C and humidity spans 20 to 90%.

Where this model fits

The LCM-40KN is used in Building & Home Automation. Its operating temperature range is -30 to 90 °C and humidity range is 20 to 90%. Dimensions are 123.5 × 81.5 × 23 mm and net weight is 240 g.

Complete technical specifications

Rev. 2026-02-09
Output
Output voltage 2-100V to 2-40V, 6 levels
Rated current 350mA / 500mA / 600mA / 700mA / 900mA / 1050mA
Output profile selectable
Rated power 42 W
Number of outputs 6
Output point 350mA DIP 2 ~ 100V / 350mA
Output point 500mA DIP 2 ~ 80V / 500mA
Output point 600mA DIP 2 ~ 67V / 600mA
Output point 700mA DIP default 2 ~ 57V / 700mA(default)
Output point 900mA DIP 2 ~ 45V / 900mA
Output point 1050mA DIP 2 ~ 40V / 1050mA
Input
AC input range 180–295 VAC
DC input range 220–392 VDC
Frequency range 47–63 Hz
Power factor 0.95
Power factor correction Supported
Environmental
Operating temperature -30 to 90 °C
Storage temperature -40 to 80 °C
Operating humidity 20–90 % RH
Vibration 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
Mechanical
Dimensions (L × W × H) 123.5 × 81.5 × 23 mm
Net weight 240.0 g
Safety & compliance
Safety standards ENEC BS EN/EN61347-1, BS EN/EN61347-2-13, BS EN/EN62384 independent, BIS IS15885(Part2/Sec13), EAC TP TC 004 approved, GB/T19510.1 and GB/T19510.213(by request) ; According to BS EN/EN50172, BS EN/EN 60598-2-22, BS EN/EN61347-2-13 appendix J suitable for emergency installations(EL)(AC Input: 200-240Vac)

These approvals are recorded for the series as a whole. Where a line names particular models or ratings, it applies only to those — read it against this part number, and ask us for the certificate if your approval process needs it.

Identification
Part number LCM-40KN
Brand MEAN WELL
Category AC/DC KNX
Series LCM-40KN

Approvals and compliance

From the manufacturer's datasheet for this series

Europe

  • ENEC

    ENEC is a pan-European mark for electrical equipment, issued by a national certification body and recognised across the member schemes. It covers both product testing and factory surveillance, which is what separates it from a self-declared CE mark.

Eurasian Economic Union

  • EAC

    Conformity with the Eurasian Economic Union technical regulations, covering Russia, Belarus, Kazakhstan, Armenia and Kyrgyzstan. TP TC 004 is the low-voltage regulation and TP TC 020 the electromagnetic-compatibility one, so which number appears tells you what was assessed.

India

  • BIS

    Registration under India's Compulsory Registration Scheme, against an IS standard. IS 13252 is the Indian transposition of IEC 60950-1 and IS 15885 of IEC 61347, so the IS number identifies the product category.

Isolation and electromagnetic compatibility
Withstand voltage I/P-O/P:3.75KVAC
Isolation resistance I/P-O/P:>100M Ohms / 500VDC / 25℃/ 70% RH
EMC emission Compliance to BS EN/EN55015, BS EN/EN61000-3-2 Class C(@load≧40%) ; BS EN/EN61000-3-3; GB/T 17743, GB17625.1 EAC TP TC 020
EMC immunity Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN61547, light industry level(surge immunity Line-Line 2KV), EAC TP TC 020

Standards certified against

  • EN 60598-2-22
  • EN50172
  • EN61347-1
  • EN61347-2-13
  • EN62384
  • GB/T19510.1
  • GB/T19510.213
  • IS15885
Read the datasheet's exact wording

ENEC BS EN/EN61347-1, BS EN/EN61347-2-13, BS EN/EN62384 independent, BIS IS15885(Part2/Sec13), EAC TP TC 004 approved, GB/T19510.1 and GB/T19510.213(by request) ; According to BS EN/EN50172, BS EN/EN 60598-2-22, BS EN/EN61347-2-13 appendix J suitable for emergency installations(EL)(AC Input: 200-240Vac)

Reproduced unedited from the manufacturer's datasheet. Where an approval covers only some models, the wording says so. Ask us for the certificate itself if your approval process needs it.

Certificates

Certificate copy supplied with this model.
  • CE · R50453592

    100%
    CE certificate R50453592

    CE · Certificate number R50453592

Ordering & shipping information

Order and delivery terms
Part number LCM-40KN
Minimum order quantity 1
Country of origin China
Typical packed weight 428 g
Unit weight 240 g

LCM-40KN model comparison

View all models
ModelOutput voltageRated currentRated powerPriceAvailability
LCM-40KN Currently viewing2-100V to 2-40V, 6 levels350mA / 500mA / 600mA / 700mA / 900mA / 1050mA42 W$51.92
Ships in 3–5 business days

Request a bulk quote

Tell us the quantity and target date and we will come back with pricing, lead time and stock position for this part number.

  1. 1 We confirm the part number and quantity against current stock.
  2. 2 You receive pricing, lead time and freight options by email.
  3. 3 Approve the quotation and we issue the invoice and shipping documents.

Request a quote for LCM-40KN

Confirm quantity and destination and we will come back with pricing and lead time.

Quoting LCM-40KN View
Have a BOM? Reply to our confirmation email with the file attached.
We use your details only to answer this request.

Technical data source

Primary source
MEAN WELL
Datasheet revision
2026-02-09
Last verified

View the manufacturer datasheet How we source and verify product data

Specifications are transcribed from the manufacturer datasheet and are subject to change without notice. The current manufacturer datasheet governs in case of any discrepancy.