MEAN WELL HRPG-600-36 630W 36V 17.5A Enclosed Type

Part numberHRPG-600-36
Output voltage 36 V
Rated current 17.5 A
Rated power630 W
$233.08Excluding tax and shipping
In stock Ships in 3–5 business daysLead time is the time from order to dispatch, and does not include transit time.
Request bulk quote

Procurement confidence

  • Genuine product Sourced through our documented supply chain.
  • Worldwide shipping Export documentation handled for you.
  • Commercial invoice Available for every order.
  • Specification support Talk to someone who reads datasheets.
Output
Rated power 630 W
Output voltage 36 V
Rated current 17.5 A
AC input range 85–264 VAC
Typical efficiency 89 %
Mechanical
Operating temperature -40 to 70 °C
Power factor correction Supported
Dimensions (L × W × H) 218 × 105 × 63.5 mm

Is this model right for you?

Within the HRPG-600 series, choose by output voltage and current. HRPG-600-36 lists 36 V and 17.5 A; HRPG-600-24 lists 24 V and 27 A; HRPG-600-48 lists 48 V and 13 A. Rated power also differs: 630 W for HRPG-600-36, 648 W for HRPG-600-24, and 624 W for HRPG-600-48.

Product overview

The HRPG-600-36 provides a 36 V output with a 17.5 A output current and 630 W rated power. Its output adjustment range is 28.8 to 39.6 V, and typical efficiency is 89%. The input voltage range is 85 to 264 VAC or 120 to 370 VDC at 47 to 63 Hz. Ripple and noise are 200 mVp-p.

Where this model fits

The HRPG-600-36 is used in Industrial Automation and Motor Drives. Its 36 V output and 17.5 A output current support control cabinets and machine controls. The operating temperature range is -40 to 70 °C, and the input voltage range is 85 to 264 VAC or 120 to 370 VDC.

Complete technical specifications

Rev. 2024-10-30
Output
Output voltage 36 V
Rated current 17.5 A
Rated power 630 W
Voltage adjustment range 28.8–39.6 V
Ripple & noise 200 mVp-p
Input
AC input range 85–264 VAC
DC input range 120–370 VDC
Frequency range 47–63 Hz
Typical efficiency 89 %
No-load consumption 0.75 W
Power factor 0.93
Power factor correction Supported
Environmental
Operating temperature -40 to 70 °C
Storage temperature -40 to 85 °C
Operating humidity 20–90 % RH
Vibration 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
Mechanical
Dimensions (L × W × H) 218 × 105 × 63.5 mm
Net weight 1580.0 g
Safety & compliance
Safety standards UL62368-1, TUV BS EN/EN62368-1, EAC TP TC 004 approved

These approvals are recorded for the series as a whole. Where a line names particular models or ratings, it applies only to those — read it against this part number, and ask us for the certificate if your approval process needs it.

Identification
Part number HRPG-600-36
Brand MEAN WELL
Category AC/DC Enclosed Type
Series HRPG-600

Approvals and compliance

From the manufacturer's datasheet for this series

United States

  • UL

    UL Listing or Recognition means UL Solutions tested samples against the applicable UL safety standard and audits the factory that builds them. A UL file number is the usual evidence an inspector or specifier asks for in North America.

Europe

  • TÜV

    A TÜV certificate is third-party testing against the European EN standard. It is the evidence behind a CE declaration rather than a replacement for it: CE remains the manufacturer's own declaration, and the TÜV report is what makes that declaration defensible.

Eurasian Economic Union

  • EAC

    Conformity with the Eurasian Economic Union technical regulations, covering Russia, Belarus, Kazakhstan, Armenia and Kyrgyzstan. TP TC 004 is the low-voltage regulation and TP TC 020 the electromagnetic-compatibility one, so which number appears tells you what was assessed.

Isolation and electromagnetic compatibility
Withstand voltage I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
Isolation resistance I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
EMC emission Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020
EMC immunity Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55024, BS EN/EN61000-6-2, heavy industry level, EAC TP TC 020

Standards certified against

  • EN62368-1
  • UL62368-1
Read the datasheet's exact wording

UL62368-1, TUV BS EN/EN62368-1, EAC TP TC 004 approved

Reproduced unedited from the manufacturer's datasheet. Where an approval covers only some models, the wording says so. Ask us for the certificate itself if your approval process needs it.

Certificates

Certificate copy supplied with this model.
  • CE · R50453592

    100%
    CE certificate R50453592

    CE · Certificate number R50453592

Ordering & shipping information

Order and delivery terms
Part number HRPG-600-36
Minimum order quantity 1
Country of origin China
Typical packed weight 1885 g
Unit weight 1580 g

HRPG-600 model comparison

View all models
ModelOutput voltageRated currentRated powerPriceAvailability
HRPG-600-36 Currently viewing36 V17.5 A630 W$233.08
In stock
HRPG-600-3.33.3 V120 A396 W$233.08
In stock
HRPG-600-4848 V13 A624 W$233.08
In stock
HRPG-600-1212 V53 A636 W$233.08
In stock
HRPG-600-55 V120 A600 W$233.08
In stock
HRPG-600-1515 V43 A645 W$233.08
In stock
HRPG-600-2424 V27 A648 W$233.08
In stock
HRPG-600-7.57.5 V80 A600 W$233.08
In stock

HRPG-600-36 lists 36 V output and 17.5 A output current; HRPG-600-24 lists 24 V output and 27 A output current.

HRPG-600-36 lists 630 W rated power; HRPG-600-48 lists 624 W rated power.

HRPG-600-36 lists 200 mVp-p ripple and noise; HRPG-600-12 lists 150 mVp-p ripple and noise.

Request a bulk quote

Tell us the quantity and target date and we will come back with pricing, lead time and stock position for this part number.

  1. 1 We confirm the part number and quantity against current stock.
  2. 2 You receive pricing, lead time and freight options by email.
  3. 3 Approve the quotation and we issue the invoice and shipping documents.

Request a quote for HRPG-600-36

Confirm quantity and destination and we will come back with pricing and lead time.

Quoting HRPG-600-36 View
Have a BOM? Reply to our confirmation email with the file attached.
We use your details only to answer this request.

Technical data source

Primary source
MEAN WELL
Datasheet revision
2024-10-30
Last verified

View the manufacturer datasheet How we source and verify product data

Specifications are transcribed from the manufacturer datasheet and are subject to change without notice. The current manufacturer datasheet governs in case of any discrepancy.