MEAN WELL DPU-3200-24 3192W 24V 133A Programmable Power

Part numberDPU-3200-24
Output voltage 24 V
Rated current 133 A
Rated power 3192 W
$1,506.52Excluding tax and shipping
Ships in 3–5 business daysLead time is the time from order to dispatch, and does not include transit time.
Request bulk quote

Procurement confidence

  • Genuine product Sourced through our documented supply chain.
  • Worldwide shipping Export documentation handled for you.
  • Commercial invoice Available for every order.
  • Specification support Talk to someone who reads datasheets.
Output
Output voltage 24 V
Rated current 133 A
Rated power 3192 W
AC input range 90–264 VAC
Typical efficiency 93.5 %
Mechanical
Operating temperature -30 to 70 °C
Power factor correction Supported
Dimensions (L × W × H) 325.8 × 107 × 41 mm

Is this model right for you?

The DPU-3200-24 and DPU-3200-48 differ in output voltage, output current, rated power, output adjustment range, ripple and noise, and typical efficiency. DPU-3200-24: 24 V, 133 A, 3192 W, 23.5 to 30 V, 300 mVp-p, 93.5%. DPU-3200-48: 48 V, 67 A, 3216 W, 47.5 to 58.8 V, 480 mVp-p, 94.5%.

Product overview

The DPU-3200-24 provides a 24 V output with 133 A output current and 3192 W rated power. The output adjustment range is 23.5 to 30 V, and ripple and noise is 300 mVp-p. Input voltage range is 90 to 264 VAC and 127 to 370 VDC, with a frequency range of 47 to 63 Hz. Typical efficiency is 93.5%. Dimensions are 325.8 × 107 × 41 mm and net weight is 2760 g.

Where this model fits

The DPU-3200-24 is used in Test & Measurement. Its output adjustment range is 23.5 to 30 V, ripple and noise is 300 mVp-p, and typical efficiency is 93.5%. Input voltage range is 90 to 264 VAC and 127 to 370 VDC.

Complete technical specifications

Rev. 2024-09-04
Output
Output voltage 24 V
Rated current 133 A
Rated power 3192 W
Voltage adjustment range 23.5–30 V
Ripple & noise 300 mVp-p
Input
AC input range 90–264 VAC
DC input range 127–370 VDC
Frequency range 47–63 Hz
Typical efficiency 93.5 %
Power factor 0.97
Power factor correction Supported
Environmental
Operating temperature -30 to 70 °C
Storage temperature -40 to 85 °C
Operating humidity 20–90 % RH
Vibration 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
Mechanical
Dimensions (L × W × H) 325.8 × 107 × 41 mm
Net weight 2760.0 g
Safety & compliance
Safety standards UL62368-1, CSA C22.2 No. 62368-1, TUV BS EN/EN62368-1, EAC TP TC 004 approved

These approvals are recorded for the series as a whole. Where a line names particular models or ratings, it applies only to those — read it against this part number, and ask us for the certificate if your approval process needs it.

Identification
Part number DPU-3200-24
Brand MEAN WELL
Category AC/DC Programmable Power
Series DPU-3200

Approvals and compliance

From the manufacturer's datasheet for this series

United States

  • UL

    UL Listing or Recognition means UL Solutions tested samples against the applicable UL safety standard and audits the factory that builds them. A UL file number is the usual evidence an inspector or specifier asks for in North America.

Canada

  • CSA

    Certification to a CSA C22.2 standard, the Canadian counterpart of the UL series. Datasheets cite the specific C22.2 number, which is how you tell a power-supply certificate from a luminaire-controlgear one.

Europe

  • TÜV

    A TÜV certificate is third-party testing against the European EN standard. It is the evidence behind a CE declaration rather than a replacement for it: CE remains the manufacturer's own declaration, and the TÜV report is what makes that declaration defensible.

Eurasian Economic Union

  • EAC

    Conformity with the Eurasian Economic Union technical regulations, covering Russia, Belarus, Kazakhstan, Armenia and Kyrgyzstan. TP TC 004 is the low-voltage regulation and TP TC 020 the electromagnetic-compatibility one, so which number appears tells you what was assessed.

Isolation and electromagnetic compatibility
Withstand voltage I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC
Isolation resistance I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
EMC emission Parameter Standard Test Level / Note

Standards certified against

  • EN62368-1
  • UL62368-1
Read the datasheet's exact wording

UL62368-1, CSA C22.2 No. 62368-1, TUV BS EN/EN62368-1, EAC TP TC 004 approved

Reproduced unedited from the manufacturer's datasheet. Where an approval covers only some models, the wording says so. Ask us for the certificate itself if your approval process needs it.

Certificates

Certificate copy supplied with this model.
  • CE · R50453592

    100%
    CE certificate R50453592

    CE · Certificate number R50453592

Ordering & shipping information

Order and delivery terms
Part number DPU-3200-24
Minimum order quantity 1
Country of origin China
Warranty 5-year limited warranty, subject to the conditions in MEAN WELL's published warranty statement.
Typical packed weight 3270 g
Unit weight 2760 g

DPU-3200 model comparison

View all models
ModelOutput voltageRated currentRated powerPriceAvailability
DPU-3200-4848 V67 A3216 W$1,506.52
Ships in 3–5 business days
DPU-3200-24 Currently viewing24 V133 A3192 W$1,506.52
Ships in 3–5 business days

DPU-3200-24: 24 V output, 133 A, 3192 W; DPU-3200-48: 48 V output, 67 A, 3216 W.

DPU-3200-24: output adjustment range 23.5 to 30 V; DPU-3200-48: 47.5 to 58.8 V.

DPU-3200-24: ripple and noise 300 mVp-p; DPU-3200-48: 480 mVp-p.

DPU-3200-24: typical efficiency 93.5%; DPU-3200-48: 94.5%.

Request a bulk quote

Tell us the quantity and target date and we will come back with pricing, lead time and stock position for this part number.

  1. 1 We confirm the part number and quantity against current stock.
  2. 2 You receive pricing, lead time and freight options by email.
  3. 3 Approve the quotation and we issue the invoice and shipping documents.

Request a quote for DPU-3200-24

Confirm quantity and destination and we will come back with pricing and lead time.

Quoting DPU-3200-24 View
Have a BOM? Reply to our confirmation email with the file attached.
We use your details only to answer this request.

Technical data source

Primary source
MEAN WELL
Datasheet revision
2024-09-04
Last verified

View the manufacturer datasheet How we source and verify product data

Specifications are transcribed from the manufacturer datasheet and are subject to change without notice. The current manufacturer datasheet governs in case of any discrepancy.