DC/DC On Board Type (Module Potted)

MEAN WELL RQB60W12 Series

3 products

The MEAN WELL RQB60W12 series has 4 models in the DC/DC On Board Type (Module Potted) category, part of the MEAN WELL Brick Type - 1/4 Brick. Rated power runs from 59.994W to 60W. Output voltages: 5V, 12V, 48V and 54V.

Every model in the series shares input 14 ~ 160Vdc, a 57.9 × 36.8 × 12.7 mm case and free-air convection. Approvals listed for the series include CB, EAC and UL.

Typical efficiency runs from 89% (RQB60W12-110S05) to 91.5% (RQB60W12-110S54). Open a model for its full specification and datasheet.

3 products
MEAN WELL RQB60W12 Series
Select ModelVoltageCurrentPowerEfficiencyDimensions (L × W × H)IP ratingPriceAvailability Actions
RQB60W12-110S055 V12 A60 W89 %57.9 × 36.8 × 12.7 mm$186.34
In stock
View
RQB60W12-110S4848 V1.25 A60 W90 %57.9 × 36.8 × 12.7 mm$186.34
In stock
View
RQB60W12-110S1212 V5 A60 W90 %57.9 × 36.8 × 12.7 mm$186.34
In stock
View

Approvals and compliance

From the manufacturer's datasheet for this series

United States

  • UL

    UL Listing or Recognition means UL Solutions tested samples against the applicable UL safety standard and audits the factory that builds them. A UL file number is the usual evidence an inspector or specifier asks for in North America.

International

  • CB Scheme

    A CB Test Certificate reports testing against the IEC standard and is accepted by member certification bodies as the basis for a national approval. It shortens a new-country approval rather than granting market access by itself, so it is the most useful item on this list when you are entering a market that is not shown here.

Eurasian Economic Union

  • EAC

    Conformity with the Eurasian Economic Union technical regulations, covering Russia, Belarus, Kazakhstan, Armenia and Kyrgyzstan. TP TC 004 is the low-voltage regulation and TP TC 020 the electromagnetic-compatibility one, so which number appears tells you what was assessed.

Isolation and electromagnetic compatibility
Withstand voltage I/P-O/P:3KVDC or 2KVAC
Isolation resistance I/P-O/P:1000M Ohms / 500VDC / 25℃/ 70% RH non-condensing
EMC emission Parameter Standard Test Level / Note

Standards certified against

  • IEC62368-1
  • UL62368-1
Read the datasheet's exact wording

CB IEC62368-1, UL62368-1, EAC TP TC 020/2011 approved

Reproduced unedited from the manufacturer's datasheet. Where an approval covers only some models, the wording says so. Ask us for the certificate itself if your approval process needs it.

Request a bulk quote

Choosing between several models in this series? Send us the shortlist and we will come back with pricing, lead time and stock for each part number.

  1. 1 Tell us the models and quantities you are considering.
  2. 2 We confirm availability and send tiered pricing for the series.
  3. 3 Approve the quotation and we issue the invoice and shipping documents.

Request a quote: MEAN WELL RQB60W12 Series

Select the models you need, or describe your requirement and we will help you choose.

Request a quote for multiple models
Have a BOM? Reply to our confirmation email with the file attached.
We use your details only to answer this request.