Power Supply Ripple and Noise: Read the Specification
What mVp-p ripple ratings mean, the 20MHz bandwidth and 0.1μF/47μF test setup, and why LRS-350, NDR-240 and DDR-120 figures compare only like for like.
Read a ripple and noise figure together with its measurement note. In the PDFs used here it is a maximum peak-to-peak value in mVp-p, measured at 20MHz of bandwidth with a 12-inch twisted pair terminated by 0.1μF and 47μF capacitors: 150mVp-p for the 24V columns of LRS-350 and NDR-240, and 50mVp-p for the DDR-120 C-type 24V column. Compare figures only when those conditions match, relate them to the equipment's own documented limit, and note that a constant-current LED driver such as LPC-60 states current ripple in percent instead, which is a different quantity.
Ripple vs Noise and mVp-p Units
Ripple is the periodic variation left on a DC output at the supply's switching or line-related frequencies; noise is the higher-frequency spikes on top of it. Power supply PDFs usually state the two together as a peak-to-peak value, the difference between the highest and lowest point of the waveform, in millivolts peak-to-peak (mVp-p). A peak-to-peak figure is not an RMS figure, and the two cannot be converted into each other without knowing the waveform.
Constant-current LED drivers can use a different quantity altogether. LPC-60 lists a current ripple of ±5% rather than a voltage in mVp-p, measured over 60%~100% of maximum voltage under rated power delivery, so it describes variation in the LED current, not in a regulated output voltage.
20MHz Bandwidth and Other Ripple Test Notes
Every ripple row points to a note, and the note defines the number. LRS-350, NDR-240 and DDR-120 all state that ripple and noise are measured at 20MHz of bandwidth using a 12-inch twisted pair-wire terminated with a 0.1μF and 47μF parallel capacitor. The rows are marked max., and the other conditions come from Note 1: rated load and 25℃ ambient, at 230VAC input for LRS-350 and NDR-240 and at a normal input of 48Vdc for the DDR-120 C type.
Record each of these conditions with the value. If a PDF does not state one of them, such as the load point or the input voltage, leave it open rather than assuming it matches another supplier's method.
Comparing Ripple Figures Across LRS-350, NDR-240 and DDR-120
Two figures are comparable only when bandwidth, probe arrangement, termination, load and input match. Within the three voltage-output examples those conditions are printed the same way, so their values can be set side by side; the LED driver's current ripple cannot.
| Series and column | Value (max.) | Quantity | Bandwidth and termination | Other conditions |
|---|---|---|---|---|
| LRS-350, 24V | 150mVp-p | Output voltage ripple and noise | 20MHz; 12-inch twisted pair with 0.1μF and 47μF | 230VAC input, rated load, 25℃ |
| NDR-240, 24V | 150mVp-p | Output voltage ripple and noise | 20MHz; 12-inch twisted pair with 0.1μF and 47μF | 230VAC input, rated load, 25℃ |
| DDR-120 C type, 24V | 50mVp-p | Output voltage ripple and noise | 20MHz; 12-inch twisted pair with 0.1μF and 47μF | 48Vdc normal input, rated load, 25℃ |
| LPC-60, 1050mA | ±5% | LED current ripple | Not stated | 60%~100% of maximum voltage, rated power |
Ripple vs the Equipment's Input Limit
The useful comparison is with the equipment that receives the power, not with an assumed universal limit. As a share of a 24V output, 150mVp-p is about 0.625% and 50mVp-p about 0.21%, but only the equipment's own documentation says what level it tolerates and how that level is measured.
Hypothetically, if an instrument's manual allowed 100mVp-p measured by the same method, the 50mVp-p rating would sit inside it and the 150mVp-p ratings would not; if the manual used a different bandwidth or method, neither comparison would hold. Wiring, grounding and nearby equipment can add noise at the load that the supply's own figure does not include, so a specification is a starting point, not proof.
Measuring Ripple Safely
Measuring the output of a switching supply involves mains voltages inside the equipment and can create hazards, including through the grounding of test instruments. Measurements should be made by qualified personnel following the manufacturer's method and the site's safety rules; this guide gives no oscilloscope procedure.
When a measurement is needed for a comparison or a complaint, it should reproduce the documented conditions as closely as possible and record every deviation.
When a Ripple Specification Is Incomplete
If a ripple figure is missing a condition, or the equipment needs a lower level than the PDF lists, ask for the evidence rather than assuming. The product data policy explains the sources behind the catalog values.
- Exact model and the ripple row and note it refers to
- Bandwidth, probe arrangement and termination used
- Load current and input voltage during the measurement
- The equipment's documented ripple limit and its measurement method
- Cable length and grounding arrangement between supply and load
- Measurements collected by qualified personnel, with their conditions
Frequently asked questions
Can I compare mVpp values measured at different bandwidths?
No. A wider bandwidth captures more high-frequency noise, so the same output can show different mVp-p values at different bandwidths. The PDFs used here state 20MHz with a defined probe arrangement; a figure measured another way is not directly comparable.
Does low ripple prove compatibility?
No. It shows only the supply's output under the stated measurement conditions. The equipment's own tolerance, the wiring and grounding, and other noise sources decide whether the installation works, so the equipment documentation remains the reference.
What details should accompany a noise complaint?
The exact model, the load and input conditions, the bandwidth, probe arrangement and termination used, the equipment's documented limit and method, the cable length and grounding, and measurements collected by qualified personnel with their conditions.
Information needed for a configuration check
- The equipment's documented ripple and noise limit and its measurement method
- Load current and input voltage at the installation
- Cable length and grounding arrangement between supply and load
- Measurements collected by qualified personnel, with their conditions
Manufacturer documents used
- LRS-350-SPEC.PDF, consulted page 2
- NDR-240-SPEC.PDF, consulted page 2
- DDR-120-SPEC.pdf, consulted page 3
- LPC-60-SPEC.PDF, consulted page 1