How to Select an Industrial DC-DC Converter
Choose an industrial DC-DC converter by input range, output current, isolation, mounting and temperature, with a DDR-120B-24 vs SD-100B-24 comparison.
Select an industrial DC-DC converter from the real behaviour of the DC source rather than its nominal voltage: its lowest, normal and highest values including transients, then the output rails and load profile, the isolation the system requires, and the thermal and mounting limits. A nominal 24V bus fits DDR-120B-24, with its 16.8 ~ 33.6VDC input, but falls outside the 19 ~ 36VDC input of SD-100B-24 whenever it sags below 19V. Isolation test voltages and approvals also differ by model and type, and neither establishes a system approval on its own.
DC Source Voltage Range: Minimum, Nominal, Maximum
Start with the source, and describe it with three numbers rather than one: the lowest voltage it reaches, for example on a discharged battery or a long cable, its normal voltage, and the highest it reaches, including charging and transients. The source equipment's documentation should supply these; a nominal label such as 24V does not.
Then compare each state with the converter's documented input. DDR-120B-24 accepts 16.8 ~ 33.6VDC and lists an under voltage lockout that switches on at 16.8V or more and off at 16.5V or less, with a normal input of 24Vdc. SD-100B-24 accepts 19 ~ 36VDC. Hypothetically, a 24V battery bus that ranges from 18V to 29V stays inside the DDR-120B range but drops below the SD-100B range at its low end.
Output Rails and Load Current
Record every output rail with its continuous current and any peaks, instead of starting from watts. DDR-120B-24 is rated at 24V, 5A and 120W, with a peak current of 7.5A and peak power of 180W for 3 seconds; its overload behaviour works within 150% for more than 3 seconds and then limits current at 105~135% with auto-recovery. SD-100B-24 is rated at 24V, 4.2A and 100.8W, adjusts over 23 ~ 30VDC and lists overload protection at 105 ~ 135% in hiccup mode.
For a hypothetical load of 3.5A continuous with a 6.0A peak for 2 seconds, DDR-120B-24 runs at 70% of its rating and the peak stays within its documented 7.5A for 3 seconds. SD-100B-24 runs at about 83%, but the peak, 144W at 24V, is about 143% of its 100.8W rating and therefore above its documented overload band.
Isolation Requirements: DDR-120 and SD-100
Decide what isolation the system needs before comparing figures. DDR-120 lists withstand voltages of I/P-O/P 4KVdc with reinforced isolation and I/P-FG and O/P-FG 2.5KVdc; SD-100 lists I/P-O/P 1.5KVAC, I/P-FG 1.5KVAC and O/P-FG 0.5KVAC. These are product test voltages, not a statement that the converter satisfies a particular system's insulation or safety requirement.
Approvals differ by model and by type within a series. DDR-120 lists IEC 62368-1, UL 62368-1, EAC TP TC 004 and AS/NZS 62368.1 approvals together with railway standards. SD-100 lists IEC/BS EN/EN62368-1 for its D type only, plus EAC TP TC 004, with AS/NZS 62368.1 as a design reference, so the B type relied on here does not carry the 62368-1 approval shown for the D type.
Mechanical Format and Temperature Range: DDR-120 vs SD-100
Mechanical format and temperature range follow the product family. DDR-120 is a DIN-rail unit of 32*125.2*102mm, cooled by free air convection and rated for -40 ~ +70℃ with a derating curve and an operating altitude of 5000 meters. SD-100 is an enclosed unit of 199*98*38mm rated for -10 ~ +60℃ for its B, C and D types, with its own derating curve, and a terminal block with DC input V+ and V- on pins 1 and 2, FG on pin 3, -V on pins 4 and 5 and +V on pins 6 and 7.
Read each derating curve at the real ambient and mounting, and allow for low-input derating where the PDF notes it; the derating guide explains how to read the curves.
DDR-120B-24 vs SD-100B-24 Comparison
The matrix sets the two records against the hypothetical source and load, and marks what is still unknown.
| Check | DDR-120B-24 | SD-100B-24 |
|---|---|---|
| Input range | 16.8 ~ 33.6VDC; lockout on at 16.8V, off at 16.5V | 19 ~ 36VDC |
| Hypothetical bus 18V to 29V | Inside the range | Low end below 19V |
| Rated output | 24V, 5A, 120W | 24V, 4.2A, 100.8W |
| Peak or overload | 7.5A and 180W for 3 seconds | 105 ~ 135%, hiccup |
| Hypothetical 6.0A peak | Within the documented peak | About 143% of rated power; above the overload band |
| I/P-O/P withstand | 4KVdc, reinforced | 1.5KVAC |
| 62368-1 approval listed | Yes | D type only |
| Mounting and size | DIN rail; 32*125.2*102mm | Enclosed; 199*98*38mm |
| Working temperature | -40 ~ +70℃ | -10 ~ +60℃ |
| Source transients and system isolation need | Unknown; source documents needed | Unknown; source documents needed |
DC-DC Converter Procurement Checklist
A procurement request that includes the application and the source behaviour gets a checked answer rather than a guess.
- Application and source type, such as battery, vehicle bus or DC plant
- Lowest, normal and highest source voltage, including transients and their duration
- Each output rail: voltage, continuous current and peaks
- Required isolation and approvals for the system
- Mounting, ambient temperature and altitude
- Quantity and destination
Frequently asked questions
Does the nominal input voltage describe the complete range?
No. A nominal figure hides the low and high states that matter. A bus labelled 24V that falls to 18V stays inside the 16.8 ~ 33.6VDC input of DDR-120B-24 but leaves the 19 ~ 36VDC input of SD-100B-24.
Does isolated mean approved for every system?
No. An isolation figure is a product test voltage, and approvals are listed per model and type: SD-100, for example, lists its 62368-1 approval for the D type only. The system's own insulation and approval requirements decide whether a converter can be used.
Can a converter be selected by output watts alone?
No. Input range, peaks, overload behaviour, isolation, approvals and temperature range can rule a converter in or out regardless of its wattage. In the hypothetical example, a 6.0A peak separated two 24V converters that both cover the continuous load.
Information needed for a configuration check
- Lowest, normal and highest source voltage, including transients
- Each output rail with continuous and peak current
- Required isolation and approvals for the system
- Mounting, ambient temperature and altitude
Manufacturer documents used
- DDR-120-SPEC.pdf, consulted pages 1, 2
- SD-100-SPEC.PDF, consulted pages 1, 2